KENNERDELL, PA —
OSHA Inspection: WITHERUP FABRICATION & ERECTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WITHERUP FABRICATION & ERECTION, INC. in 431 KENNERDELL ROAD, KENNERDELL, PA 16374 (NAICS 332420). OSHA activity number 339653636.
Where did this inspection happen?
- Establishment
- WITHERUP FABRICATION & ERECTION, INC.
- Site address
- 431 KENNERDELL ROAD
- City
- KENNERDELL
- State
- PA
- ZIP
- 16374
- Mailing
- 431 KENNERDELL ROAD, KENNERDELL, PA 16374
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2040.00 · Current $1530.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: Two employees accessed the top of a 16-feet tank to disconnect a mobile crane hook from the tank, and to secure the tank's spreader bar. The tank was not equipped with a standard guardrail system when preforming these tasks, and exposed to a 16-feet fall hazard. IN THE ALTERNATIVE: 29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 27, 2014 and times prior thereto: Two employees accessed the top of a 16-feet tank to disconnect a mobile crane hook from the tank, and to secure the tank's spreader bar. Employees were not utilizing personal fall arrest systems when preforming these tasks, and exposed to a 16-feet fall hazard.
Recent events (2)
- — I (S) $1530
- — Z (S) $2040
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $765.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: Sheets of carbon steel were stacked in front of an emergency exit door. The placement of the sheets of carbon steel allowed for an 11-inch path of egress between the steel and an adjacent Lincoln Electric DC-400 welding unit.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $765.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: Employees on-site performing servicing and maintenance on various machinery including, but not limited to, a 10-ton overhead crane and a 25-ton overhead crane. The lockout tagout procedures did not include specific information regarding the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy; a specific statement of the intended use of the procedure; specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: Employees on-site performing servicing and maintenance on various machinery including, but not limited to, a 10-ton overhead crane and a 25-ton overhead crane. Periodic inspections of the lockout tagout procedures were conducted annually, however the periodic inspections were not certified.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $1020.00 · Current $765.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: A Lincoln Electric DC-400 welding unit, and two carbon dioxide cylinders used for production purposes were stored in front of electrical disconnect #79, #80, #81, and #82.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not identify a document as a certification of hazard assessment: A.) Witherup Fabrication and Erection, Inc., 431 Kennerdell Road, Kennerdell, PA 16374, on or about March 28, 2014 and times prior thereto: The company's personal protective equipment certification has not been certified by a management official.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332420)
WRENS, GA—2026-07-08
LEWIS STEEL WORKS, INC.
THEODORE, AL—2026-06-25
CHART INDUSTRIES, INC.
BALL GROUND, GA—2026-06-09
CHART INDUSTRIES
ROLAND, OK—2026-06-02
PITTSBURG TANK & TOWER
ODESSA, TX—2026-05-26
P2 CONSTRUCTION INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16