WILMETTE, IL —
OSHA Inspection: DSL CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of DSL CONSTRUCTION, INC. in 3 CANTERBURRY CT., WILMETTE, IL 60091 (NAICS 238350). OSHA activity number 339657090.
Where did this inspection happen?
- Establishment
- DSL CONSTRUCTION, INC.
- Site address
- 3 CANTERBURRY CT.
- City
- WILMETTE
- State
- IL
- ZIP
- 60091
- Mailing
- 15100 OLD ROCKLAND ROAD, LIBERTYVILLE, IL 60048
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $2400.00
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely encloses that portion of the saw above the table and above the material being cut: a) A Royobi table saw was not equipped with a blade guard when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — A (S) $2400
- — I (S) $1080
- — Z (S) $2400
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) A Royobi table saw was not equipped with a spreader when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) A Royobi table saw was not equipped with non-kickback fingers or dogs when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) The electrical power cord for a Royobi table saw was without a ground. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DSL CONSTRUCTION, INC.
SOMERS, NY—2010-04-15 00:00:00
DSL CONSTRUCTION INC
KENILWORTH, IL—2009-05-05 00:00:00
DSL CONSTRUCTION, INC.
View DSL CONSTRUCTION, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ