Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HUDSON VALLEY CREAMERY, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of HUDSON VALLEY CREAMERY, LLC in 2986 ROUTE 9, HUDSON, NY 12534 (NAICS 311513). OSHA activity number 339657652.

Watch Hudson Valley Creamery, LLC — free Get an email when a new federal OSHA severe-injury report for Hudson Valley Creamery, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2986 ROUTE 9
City
HUDSON
State
NY
ZIP
12534
Mailing
2986 ROUTE 9, HUDSON, NY 12534
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1600.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) Maintenance operations, anhydrous ammonia system:  On or prior to 3/27/14, a written respiratory protection program was not established for use of the Sperian-Survivair full facepiece respirator.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2000

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) Maintenance operations, anhydrous ammonia system:  On or prior to 3/27/14, employee was not medically evaluated prior to use of the Sperian-Survivair full facepiece respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:    (a) Maintenance operations, anhydrous ammonia system:  On or prior to 3/27/14, employee did not have a fit test prior to use of the Sperian-Survivair full facepiece respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:    (a) Maintenance and emergency operations, anhydrous ammonia system:  On or prior to 3/27/14, the employer did not select a self-contained breathing apparatus (SCBA) or similar respirator suitable for entry into an immediately dangerous to life and health (IDLH) atmosphere, which could occur in the event of a leak or emergency situation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View HUDSON VALLEY CREAMERY, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339657652.