PANAMA CITY, FL —
OSHA Inspection: CHASAL TRIM, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHASAL TRIM, INC. in 4904 CHRISTY LANE LOT 10, PANAMA CITY, FL 32405 (NAICS 238160). OSHA activity number 339661845.
Where did this inspection happen?
- Establishment
- CHASAL TRIM, INC.
- Site address
- 4904 CHRISTY LANE LOT 10
- City
- PANAMA CITY
- State
- FL
- ZIP
- 32405
- Mailing
- 220 LA CANOSA BLVD., SANTA ROSA BEACH, FL 32459
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $5390.00 · Current $2695.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about April 3, 2014, roof area, employees installing black felt paper were not protected from falling 9 feet by the use of a guardrail system, safety net system, personal fall arrest system or any other type fall protection method. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
1926.1053 B01
- Issued
- Penalty
- Initial $5390.00 · Current $2695.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladders length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder: a. On or about April 3, 2014, employees were using a "Little Giant" ladder that was not secured to prevent accidental displacement, exposing the employees to fall hazards. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $2695
- — Z (S) $5390
More inspections at CHASAL TRIM, INC.
PANAMA CITY, FL—2014-04-01 00:00:00
CHASAL TRIM, INC.
View CHASAL TRIM, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source