TORRINGTON, CT —
OSHA Inspection: TORRINGTON HEALTH & REHABILITATION CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TORRINGTON HEALTH & REHABILITATION CENTER in 225 WYOMING AVENUE, TORRINGTON, CT 06790 (NAICS 623110). OSHA activity number 339674285.
Where did this inspection happen?
- Establishment
- TORRINGTON HEALTH & REHABILITATION CENTER
- Site address
- 225 WYOMING AVENUE
- City
- TORRINGTON
- State
- CT
- ZIP
- 06790
- Mailing
- 225 WYOMING AVENUE, TORRINGTON, CT 06790
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623110
- Employees
- 135
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $3780.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: Roof of Facility: On, or about, February 23, 2014, employees were assigned to remove a large accumulation of snow from the flat roof of the facility. Employees were not provided with fall protection equipment and were exposed to fall distances of up to 22 feet to the ground below.
Recent events (2)
- — I (S) $3780
- — Z (S) $6300
1910.151 C
- Issued
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes were not provided within the work area for immediate emergency use: Laundry Department: On, or about, April 11, 2014, an eyewash unit that supplied at least 15 minutes of continuous flow was not provided where employees changed five gallon containers of corrosive laundry products such as Proline Commerial White and Proline Commercial HD Detergent.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.212 A03 II
- Issued
- Penalty
- Initial $3825.00 · Current $2295.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A. Outside of Building: On, or about, April 11, 2014, the trash compactor was not provided with adequate safeguarding in that the ram could be reached during the operating cycle of the compactor. B. Dietary: On, or about, April 11, 2014, the meat grinder attachment provided for use on the Univex mixer allowed entry to the rotating blade through the disk attachment. On January 28, 2012, an employee suffered a partial finger amputation while using the machine.
Recent events (2)
- — I (S) $2295
- — Z (S) $3825
1910.303 G01 I A
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: Basement Housekeeping Closet: On, or about, April 11, 2014, a GE circuit breaker panel was not provided with adequate working space in that it was blocked by a sump hole/pump installation and its associated piping.
Recent events (2)
- — I (S) $0
- — Z (S) $2295
1910.304 A02
- Issued
- Penalty
- Initial $3060.00 · Current $1836.00 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: Hair Salon: On, or about, April 11, 2014, three wall mounted receptacles were found to be wired with reversed polarity.
Recent events (2)
- — I (S) $1836
- — Z (S) $3060
1910.37 B05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g., closet): Recreation Room: On, or about, April 11, 2014, the exterior door leading to an enclosed patio area was not provided with a sign to indicate its function or a "not an exit sign".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1030 C01 II B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1030(c)(1)(ii)(B): The employer's Exposure Control Plan did not include the schedule and method of implementation for 29 CFR 1910.1030(f), Hepatitis B Vaccination and Post-Exposure Evaluation and Follow-up: Facility: On, or about, April 21, 2014, the Exposure Control Plan did not address the recommended guidelines to be followed in the event that an employee did not have an adequate response to a second Hepatitis B vaccination series. The current recommended practice by the Centers for Disease Control and Prevention is to have the employee medically evaluated.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: Outside of Building: On, or about, April 11, 2014, the fuel tank provided for the back-up generator was not labeled to indicate the identity of the contents. The fuel tank contained diesel fuel, a Category 3 flammable liquid.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Outside of Building: On, or about, April 11, 2014, the fuel tank provided for the back-up generator was not labeled with the appropriate hazard warning(s) for the diesel fuel, a Category 3 flammable liquid.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 623110)
GRANTS PASS, OR—2026-07-07
317744714 - CASCADE LIVING GROUP - GRANTS PASS LLC
TIFFIN, OH—2026-06-30
670 OH OPCO, LLC
EDMONDS, WA—2026-06-25
WA317991719 - KALESTA HEALTHCARE GROUP LLC
LINCOLNTON, NC—2026-06-24
161444 - LINCOLNTON REHABILITATION CENTER, LLC
CENTRALIA, WA—2026-06-23
WA317991797 - PROVIDENCE HEALTH & SERVICES WASHINGTON
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source