Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAST END

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EAST END in 123 WILLIAM STREET, PECK SLIP, NY 10038 (NAICS 531390). OSHA activity number 339674632.

Watch East END — free Get an email when a new federal OSHA severe-injury report for East END is published. One employer, no account, unsubscribe in one click.
Establishment
EAST END
Site address
123 WILLIAM STREET
City
PECK SLIP
State
NY
ZIP
10038
Mailing
123 WILLIAM STREET, PECK SLIP, NY 10038
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531390
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1500.00 Reduced
29 CFR 1926.403(b)(2): Installation and use. Em[loyer did not ensure Listed, labeled, or certified equipment were installed and used in accordance with instructions included in the listing, labeling, or certification.    Location: 123 William Street, New York, NY 10038, Main floor lobby, Northwest side behind Newspaper Stand.    a). Employees working/walking in the area of the lobby under renovation were exposed to electrical shock/burn hazards because at least one 1900 outlet recepticle was not properly secured to a fixed object.     NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2800

1926.405 G01 III A

Serious Gravity 5 1 instance 12 exposed
Issued
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1926.405(g)(1)(iii)(A): Employer did not ensure temporary flexible extension cords were not used as a substitute for the fixed wiring of a structure;    Location: 123 William Street, New York, NY 10038, Ground Floor Lobby behind Newspaper Stand.    A). During renovation project effecting the Lobby area of the first floor, employees had utilized a flexible extension cord drawing power from a hard wired, square metal "1900" junction box, and wired directly into the bare, exposed wires to energize the exhaust fan of the Newspaper Stand.    NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.405 G02 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.405(g)(2)(iv): Strain relief. Employer did not ensure Flexible cords were connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    a). 123 William Street, ZGround FLoor lobby, behind newspaper stand.    Employees working/walking within the renovation area of the lobby were exposed to electrical shock/burn hazards because the electrical feed to the 1900 recepticle box (unsecured and laying on the floor), was pulled from teh junction opening and clamp and exposed wires were visible.     NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339674632.