Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PETERSEN DEAN ROOFING & SOLAR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETERSEN DEAN ROOFING & SOLAR in 1841 CRYSTAL FALLS PARKWAY, LEANDER, TX 78641 (NAICS 238160). OSHA activity number 339691701.

Watch Petersen Dean Roofing & Solar — free Get an email when a new federal OSHA severe-injury report for Petersen Dean Roofing & Solar is published. One employer, no account, unsubscribe in one click.
Site address
1841 CRYSTAL FALLS PARKWAY
City
LEANDER
State
TX
ZIP
78641
Mailing
13804 TURBINE DRIVE, AUSTIN, TX 78728
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $0.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.   On 16 April 2014, five roofers were installing shingles on the roof of a commercial building under construction with a pneumatic nail gun without the use of eye protection, exposing the workers to the hazard of being struck by flying objects or debris.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1926.501 B10

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $6000.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by the use of a guardrail system, safety net system, personal fall arrest system, warning line system, or a safety monitoring system.   On 16 April 2014, three workers were installing roofing shingles on a low sloped roof of a commercial building under construction without fall protection, exposing the workers to a fall hazard of approximately 10 feet 8 inches to the ground below.  Petersen Dean Roofing and Solar Systems was previously cited for an Other-Than-Serious violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 312924798, citation number 01, item number 001 and was affirmed as a final order on 11/19/2010, with respect to a workplace located at 7626 Broadway, Galveston, TX 77553.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6000

1926.1053 B01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access.   On 16 April 2014, five roofers gained access to the roof of a commercial building under construction by means of a 24 foot aluminum extension ladder that was not extended at least 3 feet beyond the roof edge, exposing the workers to a fall hazard of approximately 10 feet 8 inches to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000