Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CENTRAL MAINE HARLEY DAVIDSON, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CENTRAL MAINE HARLEY DAVIDSON, INC. in 2387 ROUTE 2, HERMON, ME 04401 (NAICS 441228). OSHA activity number 339713901.

Watch Central Maine Harley Davidson, INC. — free Get an email when a new federal OSHA severe-injury report for Central Maine Harley Davidson, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2387 ROUTE 2
City
HERMON
State
ME
ZIP
04401
Mailing
2387 ROUTE 2, HERMON, ME 04401
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441228
Employees
23
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):   Shop - The motorcycle storage area, nine feet above the floor, was not provided with standard railings.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.22 D01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  Shop - The approved floor load for the motorcycle storage area was not marked on a plate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    Shop - The employer did not assess the workplace to determine if hazards are present which necessitate the use of personal protective equipment (PPE).
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts:  Shop - The Craftsman drill press was not equipped with a chuck guard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 B

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  Shop - The Craftsman drill press was not mounted to the floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven (7) feet or less from floor or working platform was not enclosed with stationary casing(s):  Shop - The shaft on the motor of the Craftsman drill press was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Shop - The pulley on the Craftsman drill press was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 A

Serious Gravity 5 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.242(a): Equipment was not kept in safe condition:  In the following instances equipment was not maintained in a safe condition:  a) Shop - The garage door contained a bent track, dislodged roller, and was propped open with a pipe. b) Shop - Two Handy Air Lifts were not equipped with foot pedals. c) Shop - Handy Air Lift 95505 was operated with a damaged air hose.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.1200 E01

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):    Shop - The employer did not develop a written hazard communication program.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339713901.