Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HYDRATECH INDUSTRIES FLUID POWER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HYDRATECH INDUSTRIES FLUID POWER, INC. in 22955 MCAULIFFE DRIVE, ROBERTSDALE, AL 36567 (NAICS 333995). OSHA activity number 339729709.

Watch Hydratech Industries Fluid Power, INC. — free Get an email when a new federal OSHA severe-injury report for Hydratech Industries Fluid Power, INC. is published. One employer, no account, unsubscribe in one click.
Site address
22955 MCAULIFFE DRIVE
City
ROBERTSDALE
State
AL
ZIP
36567
Mailing
PO BOX 2618, ROBERTSDALE, AL 36567
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333995
Employees
600
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3740.00 · Current $3740.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:      a)  22955 McAuliffe Drive, Robertsdale AL - Shop Area; On or about April 15, 2014 and at times prior thereto, the employer exposed employees to struck-by hazards in that employees were allowed to walk and work around steel storage racks which were damaged and the column base plates were not anchored to the floor.
Recent events (1)
  • — Z (S) $3740

1910.23 D01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section:    a)  Cylinder Cleaning Area; On or about April 15, 2014 and at times prior thereto the employer exposed employees to fall hazards in that employees were allowed to walk up and down fixed stairs with four or more risers that did not have a standard stair rail which included a mid-rail.
Recent events (1)
  • — Z (O) $0

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:   a)  Painting Area; On or about April 15, 2014 and at times prior thereto the employer exposed employees to respiratory hazards in that employees were required to be worn in the work place but the employer failed to establish and implement a written respiratory protection program with worksite-specific procedures.
Recent events (1)
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:   a)  Paint Area;  On or about April 15, 2014 and at times prior thereto the employer exposed employees to potential respiratory hazards in that employees were required to wear a tight fitting full face negative pressure respirator without first being medically evaluated to ensure the employees are medically able to wear a negative pressure respirator.
Recent events (1)
  • — Z (O) $0

1910.134 F01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   a)  Paint Area;  On or about April 15, 2014 and at times prior thereto the employer exposed employees to potential respiratory hazards in that employees were required to wear a tight fitting full face negative pressure respirator without first being fit tested.
Recent events (1)
  • — Z (O) $0

1910.134 K01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii):  a)  Paint Area;  On or about April 15, 2014 and at times prior thereto the employer exposed employees to potential respiratory hazards in that employees were required to wear a tight fitting full face negative pressure respirator without first being provided training as required by the standard.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339729709.