Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SWARCO REFLEX, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SWARCO REFLEX, INC. in 900 N DENTON ST, MEXIA, TX 76667 (NAICS 327215). OSHA activity number 339742942.

Watch Swarco Reflex, INC. — free Get an email when a new federal OSHA severe-injury report for Swarco Reflex, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SWARCO REFLEX, INC.
Site address
900 N DENTON ST
City
MEXIA
State
TX
ZIP
76667
Mailing
P.O. BOX 1558, MEXIA, TX 76667
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327215
Employees
32
Ownership type
A

4 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  In the control room, where employees were scooping ice from a Manitowoc ice machine, the floor was wet and visibly soiled, exposing employees to the hazards of slipping and falling.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.141 A03 I

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:  In the control room, where employees were scooping ice from a Manitowoc ice machine, an empty plastic coffee container with inset grip was provided in lieu of a scoop that could be returned to the holder for sanitary reasons, exposing employees to the hazards of bacterial contamination.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  In the control room, where employees were scooping ice from a Manitowoc ice machine, the flexible cord powering the machine had the outer sheath pulled back from the plug and insulation was frayed with conductors subject to to physical damage, exposing employees to the hazards of electrical shock.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

1910.1200 F06

Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2295.00 · Current $1377.00 Reduced
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  (a) Outside, in the Cullett Area, where employees were filling the fuel tank on the front end loader with combustible diesel fuel, the tank was not labeled with hazard warnings.   (b) Outside, in the Cullett Area, where employees were loading recycled glass into a hopper for crushing and mixing with raw ingredient(s), a raw ingredient tank was not labeled, exposing employees to the hazards of chemicals.
Recent events (2)
  • — I (S) $1377
  • — Z (S) $2295

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339742942.