Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: POOL AUTO SALES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POOL AUTO SALES in 5503 RIDGE ROAD W, SPENCERPORT, NY 14559 (NAICS 441120). OSHA activity number 339744229.

Watch Pool Auto Sales — free Get an email when a new federal OSHA severe-injury report for Pool Auto Sales is published. One employer, no account, unsubscribe in one click.
Establishment
POOL AUTO SALES
Site address
5503 RIDGE ROAD W
City
SPENCERPORT
State
NY
ZIP
14559
Mailing
5503 RIDGE ROAD W, SPENCERPORT, NY 14559
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441120
Employees
11
Ownership type
A

11 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $500.00 Reduced
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors:    a) On or about 04/24/14 in the paint storage area; employer allowed the use of the flammable paint storage room without a raise seal or ramp at the opening and a non-self closing fire door exposing employee to flash fire.        Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1440

1910.106 D04 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iv): Ventilation. Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour.  a) On or about 04/24/14 in the paint storage area; employer failed to provide either mechanical or gravity exhaust in this area prior to storing and using flammable paints, solvents and thinners exposing employees to flash fire hazard caused by the accumulation of flammable vapors.      Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $500.00 Reduced
29 CFR 1910.107(c)(2): Open flame or spark producing equipment was not kept from a spraying area nor within 20 feet, unless separated from by a partition:    a) On or about 04/24/14 in the spraying room; employer failed to protect employees against flash fire hazard by allowing the spraying of flammable paints ( Akzo Nobel brand - Basecoat SB23 & SB 22) ,onto portions of cars and trucks at a distance of as close as four feet and as far as fifteen feet away from four sets of 8 foot general purpose dual bulb fluorescent light fixtures, located four feet above floor grade, each plugged into separate wall outlets.             Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1440

1910.107 C06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    a) On or about 04/24/14 in the spraying room; employer failed to protect employees against flash fire hazard by allowing the spraying of flammable paints ( Akzo Nobel brand - Basecoat SB23 & SB 22) ,onto portions of cars and trucks at a distance of as close as four feet and as far as fifteen feet away from four sets of 8 foot general purpose dual bulb fluorescent light fixtures, located four feet above floor grade, each plugged into separate wall outlets.             Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1080.00 · Current $0.00 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:    a) On or about 04/24/14 in the spray area; employer required employee to wear an elastomeric half face respirator ( 3M model 07192) while spray painting using paints, such as but not limited to, Basecoat SB 22 & 23 ( neurotoxin and respiratory irritant ) and did have or implement a written respiratory protection program.     Abatement Certification Required
Recent events (2)
  • — I (O) $0
  • — Z (S) $1080

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace  a) On or about 04/24/14 in the spray area; employer required employee to wear an elastomeric half face respirator ( 3M model 07192) while spray painting using paints, such as but not limited to, Basecoat SB 22 & 23 ( neurotoxin and respiratory irritant ) and did provide a medical evaluation.     Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting face piece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph.  a) On or about 04/24/14 in the spray area; employer required employee to wear an elastomeric half face respirator ( 3M model 07192) while spray painting using paints, such as but not limited to, Basecoat SB 22 & 23 ( neurotoxin and respiratory irritant ) and allowed the use of this protective equipment without providing the employee having a full beard.        Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i): 29 CFR 1910.134(g)(1)(i): The employer permitted respirators with tight-fitting face pieces to be worn by employees who have facial hair that came between the sealing surface of the face piece and the face or interfered with valve function:  a) On or about 04/24/14 in the spray area; employer required employee to wear an elastomeric half face respirator ( 3M model 07192) while spray painting using paints, such as but not limited to, Basecoat SB 22 & 23 ( neurotoxin and respiratory irritant ) and allowed the use of this protective equipment with the employee having a full beard.        Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a) On or about 04/24/14 in the spray area; employer required employee to wear an elastomeric half face respirator ( 3M model 07192) while spray painting using paints, such as but not limited to, Basecoat SB 22 & 23 ( neurotoxin and respiratory irritant ) and did not provide training on the use of this protective equipment.          Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $500.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) On or about 04/23/14 throughout the facility; employer required employees to use flammable and combustible paints, solvents, oils, and greases, such as but not limited to, Basecoat SB 22 & 23 ( flammable and neurotoxin) primer ( Nason primer 421-19 - flammable) and did not develop and implement a written hazard communication program.      Abatement Certification Required
Recent events (2)
  • — I (S) $500
  • — Z (S) $1440

1910.107 E09

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(e)(9): 29 CFR 1910.107(e)(9):  Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity.  a) On or about in the paint storage room in the spray room; employer failed to provide bonding and grounding for the waste paint drum and the plastic funnel used to dump of waste paint into the container exposing employees to flash fire.    Abatement Certification Required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339744229.