Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAVID FREED DBA FREEDS GREENHOUSE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DAVID FREED DBA FREEDS GREENHOUSE in 4536 BENEDUM DRIVE, BRIDGEPORT, WV 26330 (NAICS 111421). OSHA activity number 339744369.

Watch David Freed DBA Freeds Greenhouse — free Get an email when a new federal OSHA severe-injury report for David Freed DBA Freeds Greenhouse is published. One employer, no account, unsubscribe in one click.
Site address
4536 BENEDUM DRIVE
City
BRIDGEPORT
State
WV
ZIP
26330
Mailing
4536 BENEDUM DRIVE, BRIDGEPORT, WV 26330
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
111421
Employees
40
Ownership type
A

21 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    (a) Cutting House:  Employer did not ensure that all places of employment were kept clean and orderly as determined by the build up of items, such as, but not limited to cardboard boxes, old wooden pallets, and chemical containers, as observed on April 24, 2014.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.134 E01

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Bridgeport:  An employee is required to wear an MSA 1/2 face respirator with a chemical filter while spraying Conserve pesticide, as determined on or about April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:    (a) Bridgeport: The employer requires an employee to wear a 3M 1/2 face respirator when spraying conserve pesticide but did not establish and implement a written respiratory protection program, as determined on or about April 24, 2014.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Bridgeport:  An eyewash station was not provided for an employee using corrosive products, such as, but not limited to Clorox bleach to clean, sanitize, and sterilize trays, pots, inserts, and table tops, as determined on April 24, 2014.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.157 C01

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    (a) Cutting House:  The employer did not mount and properly identify a portable fire extinguisher, as observed on or about April 24, 2014.      (b) Cutting House:  A portable fire extinguisher hanging on the wall was not properly identified and was blocked by boxes, wooden pallets, and debris, as observed on or about April 24, 2014.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.157 C04

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:    (a) Cutting House:  A Kiddie ABC portable fire extinguisher was not fully charged and available for use, as observed on or about April 24, 2014.      (b) Cutting House/transplant table:  A Kiddie ABC portable fire extinguisher was not fully charged and available for use, as observed on or about April 24, 2014.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.157 E02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    (a)  Cutting House:  Three Kidde ABC portable fire extinguishers were not subject to a monthly inspection, as observed on April 24, 2014.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.157 E03

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) Cutting House:  Three Kidde ABC portable fire extinguishers were not subject to an annual maintenance check, as observed on April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.    (a) Bridgeport:  The employer did not provide training for employees expected by the employer to use fire extinguishers during incipient stage fires, as determined on April 24, 2014.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.178 L01 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a) Bridgeport:  An employee authorized to operate the Caterpillar forklift was not trained and evaluated by the employer, as determined on April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    (a) Pepper House and Cutting House:  The guard on the front of the 36 inch Schaffer fans located 3 foot above the floor has 1 inch openings exposing employees to a caught in hazard when moving flowering trays and walking near the fans, as determined on April 24, 2014.         ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) Cutting House:  The work rest on the right side of the 6 inch bench grinder was adjusted to 1/2 inch, as observed on or about April 24, 2014.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) Cutting House:  The tongue guard for the left abrasive wheel on the 6 inch bench grinder was not properly adjusted and the tongue guard for the right abrasive wheel was not present, as observed on or about April 24, 2014.       ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1400.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:    (a) Cutting House:  A cover was missing off the 220 volt electrical panel used to control the water system, as observed on April 24, 2015.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2100

1910.22 D01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  (a) Plug House:  The storage area above where employees work on a regular basis was not marked, as observed on April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1904.29 A

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $700.00 · Current $0.00 Reduced
29 CFR 1904.29(a):  A Log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or the Summary of Work-Related Injuries and Illnesses (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment:  (a) Bridgeport:  The OSHA Form 300 or equivalent was not used to record occupational injuries and illnesses that occur in the workplace, as determined on or about April 24, 2014.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $700

1910.132 D02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:    (a) Bridgeport:  The personal protective equipment hazard assessment was not certified, as determined on or about April 24, 2014.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting respirator is fit tested prior to initial use, whenever a different respirator facepiece (size, style, make or model) is used, and at least annually thereafter.    (a) Bridgeport:  An employee required to wear an MSA 1/2 face respirator with a chemical filter while spraying Conserve pesticide was not fit tested, as determined on or about April 24, 2014.        ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B07

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7):  Electrical equipment was not installed in a neat and workmanlike manner:  (a) Cutting House:  Romex wiring and other miscellaneous wiring ran from the power panels and switches to lights and other power sources were not secured, as observed on or about April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 C03 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.    (a) Pepper House:  The vent closer/opener power boxes are spliced together and the insulated conductors are not covered, as observed on April 24, 2014.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H03

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv):  (a) Bridgeport:  The employer did not provide training to the employees on hazards associated with materials, such as, but not limited to clorox bleach and conserve pesticide, as determined on or about April 24, 2014.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

UNKNOWN

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339744369.