Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ODESSA SIGN SOLUTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ODESSA SIGN SOLUTION in 235 EAST HIGHWAY 302, KERMIT, TX 79745 (NAICS 339950). OSHA activity number 339747842.

Watch Odessa Sign Solution — free Get an email when a new federal OSHA severe-injury report for Odessa Sign Solution is published. One employer, no account, unsubscribe in one click.
Site address
235 EAST HIGHWAY 302
City
KERMIT
State
TX
ZIP
79745
Mailing
1515 N GRANDVIEW AVE, ODESSA, TX 79761
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
13
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.    On or about April 30, 2014 the employer did not ensure that employees were protected from electrical current while working within close proximity to overhead power lines located at the job site exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.416 A03

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit.    On or about April 30, 2014 the employer did not ensure that employees were protected from electrical current prior to working within close proximity to overhead power lines located on the job site exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.20 B01

Deleted Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part.  On or about April 29, 2014 the employer failed to provide employees with a health and safety program that addressed hazards that employees may be exposed to while working exposing them to occupational associated hazards while working at various job-sites and at the sign production facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339747842.