Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOE'S AUTO SUPPLY & MACHINE SHOP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOE'S AUTO SUPPLY & MACHINE SHOP in 1448 SOMERSET RD, SAN ANTONIO, TX 78211 (NAICS 452990). OSHA activity number 339748816.

Watch Joe'S Auto Supply & Machine Shop — free Get an email when a new federal OSHA severe-injury report for Joe'S Auto Supply & Machine Shop is published. One employer, no account, unsubscribe in one click.
Site address
1448 SOMERSET RD
City
SAN ANTONIO
State
TX
ZIP
78211
Mailing
1448 SOMERSET RD, SAN ANTONIO, TX 78211
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452990
Employees
3
Ownership type
A

9 citations on file for this inspection.

1910.215 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):   Machine shop area, Central Machinery 1/2 HP bench Grinder, Item #378000,  On or about March 26, 2014, employees were exposed to a caught-in hazard while operating a stationary bench grinder with an exposed spindle end, nut, outer flange and without a side cover.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Machine shop area, Central Machinery 1/2 HP bench Grinder, Item 378000,  On or about March 26, 2014, employees were exposed to a struck-by hazard while operating a stationary bench grinder without a tool rest installed and positioned within 1/8" of the grinding wheel.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9):  Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  Machine shop area, Central Machinery 1/2 HP bench Grinder, Item 378000,  On or about March 26, 2014, employees were exposed to a struck-by hazard while operating a stationary bench grinder without an adjustable tongue installed on the end of the safety guard peripheral member at the top to maintain the open to less than 1/4".
Recent events (1)
  • — Z (S) $0

1910.219 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Machine shop area, Devilbiss Air Power Company Compressor, S/N 2U2946084,  On or about March 26, 2014, employees were exposed to a caught-in hazard while operating a portable air compressor without the guard, which covers the pulley of the compressor power transmission system, in place.
Recent events (1)
  • — Z (S) $0

1910.219 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):   Machine shop area, Devilbiss Air Power Company Compressor, S/n 2U2946084,  On or about March 26, 2014, employees were exposed to a caught-in hazard while operating a portable air compressor without the guard, which covers the belt of the compressor power transmission system, in place.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Machine shop area, Compressed Air Blow Gun,  On or about March 26, 2014, employees were exposed to a struck-by hazard while using a compressed air blow gun, which was unregulated and had a tip air pressure that was over 30 p.s.i.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:                                                               Machine shop area, Devilbiss Air Power Company Compressor, S/n 2U2946084,  On or about March 26, 2014, employees were exposed to an electrical hazard while operating a portable air compressor without the strain relief, of the 120 Volt power cord, being physically attached to the device.
Recent events (1)
  • — Z (S) $0

1910.22 A02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2):  Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  Machine shop area,  On or about March 26, 2014, employees were exposed to housekeeping issues, rain water entering building from roof, causing parts of the work space/floors to become wet, forcing/restricting workers to only perform work in dry locations.
Recent events (1)
  • — Z (O) $0

1910.334 A04

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords used in highly conductive work locations (such a those inundated with water or other conductive liquids), or in job locations where employees are likely to contact water or conductive liquids, were not approved for those locations:  Machine shop area,  On or about March 26, 2014, employees were exposed to an electrical hazard, while rain water entering building from roof, causing electrical extension cords,  on the floor, to become wet.  These extension cords were not designed for wet locations.
Recent events (1)
  • — Z (O) $0