VILLA PARK, IL —
OSHA Inspection: JAIME CAMPOS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAIME CAMPOS in VILLAGE OAKS SHOPPING CENTER ROOSEVELT RD., VILLA PARK, IL 60181 (NAICS 238130). OSHA activity number 339760423.
Where did this inspection happen?
- Establishment
- JAIME CAMPOS
- Site address
- VILLAGE OAKS SHOPPING CENTER ROOSEVELT RD.
- City
- VILLA PARK
- State
- IL
- ZIP
- 60181
- Mailing
- 8533 VESTA CT, INDIANAPOLIS, IN 46226
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
11 citations on file for this inspection.
1903.19 C01
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $400.00
General-duty citation text
29 CFR 1903.19(c)(1): Jaime Campos dba Jaime Campos failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 1 1 6/17/2014 1 2 6/17/2014 1 3a, 3b, 3c, 3d 6/17/2014 1 4a, 4b, 4c 6/17/2014 1 5 6/17/2014
Recent events (1)
- — Z (O) $400
1926.300 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On May 8, 2014 employees were exposed to the hazards associated with an amputation while using power operated chop saws. Instance 1. Employees were cutting steel studs with a Protech chop saw that was missing the blade guard. Instance 2. Employees were cutting wood with a Rigid chop saw that was missing the blade guard. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1600
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On May 8, 2014 employees were exposed to the hazards associated with an electrical shock while using a relocatable power tap to power construction equipment at a construction site. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1200
1926.403 E
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.403(e): All splices and joints and free ends of conductors were not covered with insulation equivalent to that of the conductors or with an insulating device designed for the purpose: On May 8, 2014 employees were exposed to the hazards associated with an electrical shock while using an extension cord that did not have the free end of the ground conductor covered or insulated. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1200
1926.404 B01 III D 1
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(D)(1): All equipment grounding conductors were not tested for continuity and were not electrically continuous. On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the extension cord they used did not have a continues ground conductor. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Instance 1. On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the metal framed compressor they used did not have a continues path to ground. Instance 2. On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the extension cord they were using did not have a continues path to ground. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.405 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the repaired flexible cord they used did not retain is insulating properties. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.403 I02 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as they used an electrical receptacle that had exposed wiring. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $1200
1926.405 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the two gang junction box they used for receptacles had open and unused knock-outs missing. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.405 G01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(1)(ii): Flexible cord was not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]: On May 8, 2014 employees were exposed to the hazards associated with an electrical shock as the flexible cord they used was missing an attachment plug. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On May 8, 2014 employees were not protected from a fall while working from a pump jack scaffold, exposing employees to a fall of 12'4'. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339760423.