OSHA Inspection: DUROX COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DUROX COMPANY in 12312 ALAMEDA DR., STRONGSVILLE, OH 44149 (NAICS 326291). OSHA activity number 339769879.

Watch Durox Company — free Get an email when a new federal OSHA severe-injury report for Durox Company is published. One employer, no account, unsubscribe in one click.
Establishment
DUROX COMPANY
Site address
12312 ALAMEDA DR.
City
STRONGSVILLE
State
OH
ZIP
44149
Mailing
12312 ALAMEDA DR., STRONGSVILLE, OH 44149
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326291
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  On or about May 15, 2014, the employer did not ensure the two hand control guarding device was designed and constructed to prevent the operator from having any part of their body in the danger zone during the operating cycle of the following electrical, pneumatic, and thermal powered presses;    a.  Press 401, Hull Model 359-K, Serial No. 77-A-4371 b.  Press 402, Hull Model 359-K, Serial No. 81-A-30684 c.  Altman #2 Press
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2100.00 · Current $1470.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   On or about May 15, 2014, the flexible power cord of the JLC Coffing ¼ ton electric hoist, located at the RP 506 P Press, was not fitted so that strain relief was provided to prevent the cord casing from pulling away from the cord plug.  The hoist power cord was plugged into an extension cord located between Press 401 and Press 402.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.184 E03 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(e)(3)(i): A thorough periodic inspection of alloy steel chain slings was not made on a regular basis and/or were done at intervals greater than once every 12 months:   On and about May 15, 2014, the employer did not ensure a thorough periodic inspection was performed on a four spread alloy steel chain sling used to lift molds into the mold cleaning machine.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DUROX COMPANY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339769879.