BLOOMER, WI —
OSHA Inspection: BLOOMER PLASTICS INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BLOOMER PLASTICS INC in 1710 NORTH INDUSTRIAL DRIVE, BLOOMER, WI 54724 (NAICS 326199). OSHA activity number 339779571.
Where did this inspection happen?
- Establishment
- BLOOMER PLASTICS INC
- Site address
- 1710 NORTH INDUSTRIAL DRIVE
- City
- BLOOMER
- State
- WI
- ZIP
- 54724
- Mailing
- 1710 NORTH INDUSTRIAL DRIVE, BLOOMER, WI 54724
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 69
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Plastic film production line embossing machinery; The ingoing nip points of the embossing rollers under the deckle devices were not guarded.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Plastic film production line embossing machinery: The rotating shafts at the end of the embossing rollers were not effectively guarded.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: (a) Bloomer Plastics production area; Safe load capacities were not clearly marked on the mezzanine above the office structure in the production area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BLOOMER PLASTICS INC
BLOOMER, WI—1989-12-13 00:00:00
BLOOMER PLASTICS, INC.
BLOOMER, WI—1987-02-11 00:00:00
BLOOMER PLASTICS, INC.
BLOOMER, WI—1986-10-08 00:00:00
BLOOMER PLASTICS, INC.
BLOOMER, WI—1986-05-13 00:00:00
BLOOMER PLASTICS, INC.
Bloomer, WI—1982-11-05 00:00:00
BLOOMER PLASTICS INC
View BLOOMER PLASTICS INC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
ERIE, PA—2026-07-14
CAPLUGS, LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339779571.