1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PISTON AUTOMOTIVE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PISTON AUTOMOTIVE, LLC in 1400 WARREN STREET, NORTH KANSAS CITY, MO 64116 (NAICS 336399). OSHA activity number 339782575.

Watch Piston Automotive, LLC — free Get an email when a new federal OSHA severe-injury report for Piston Automotive, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1400 WARREN STREET
City
NORTH KANSAS CITY
State
MO
ZIP
64116
Mailing
1400 WARREN STREET, NORTH KANSAS CITY, MO 64116
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
98
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II B

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3060.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  (a) Throughout facility: There were no machine specific lockout tagout procedures for machines such as, the Micropit Instrument Panel Assembly Line, and the Cooling Module Assembly Bolster and Main Line, as there were no machine shut down, and start up procedures with legible instructions.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3060

1910.305 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3060.00 · Current $1530.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Maintenance Shop: Employees were exposed to electrical hazards as the flexible cord for the Milermatic 251 Welder, did not have adequate strain relief as the outer insulation had pulled back next to the plug-in exposing interior wiring.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $3060

View PISTON AUTOMOTIVE, LLC's full OSHA safety record →