Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALTASOURCE, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ALTASOURCE, LLC in 1009 MANSELL RD. STE. J, ROSWELL, GA 30076 (NAICS 325411). OSHA activity number 339784241.

Watch Altasource, LLC — free Get an email when a new federal OSHA severe-injury report for Altasource, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALTASOURCE, LLC
Site address
1009 MANSELL RD. STE. J
City
ROSWELL
State
GA
ZIP
30076
Mailing
1009 MANSELL RD. STE. J, ROSWELL, GA 30076
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325411
Employees
21
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to explosion hazards and sharp particles flying in the air:  a) Production Area - Employees were exposed to flying plastic projectile hazards due to possible mechanical failure of the plastic polyvinyl chloride (PVC) piping system used to transport compressed air, exposing employees to serious physical hazards which could result in lacerations to the body and damage to the eyes resulting in hospitalization.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.134 C01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  Powder Room - The employer did not establish a written respiratory protection program, to include training, medical evaluations, and fit testing, for the employees required to wear an Elvex N95 disposable respirator while encapsulating pills.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339784241.