FRANKSVILLE, WI —
OSHA Inspection: JOHN'S RECYCLING SERVICE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JOHN'S RECYCLING SERVICE, INC. in 7311 OMEGA CIRCLE, FRANKSVILLE, WI 53126 (NAICS 562111). OSHA activity number 339786212.
Where did this inspection happen?
- Establishment
- JOHN'S RECYCLING SERVICE, INC.
- Site address
- 7311 OMEGA CIRCLE
- City
- FRANKSVILLE
- State
- WI
- ZIP
- 53126
- Mailing
- 7311 OMEGA CIRCLE, FRANKSVILLE, WI 53126
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) The employer had a generic energy control procedures to cover equipment such as but not limited to: compactors, conveyors, shear, and hydraulic press.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.147 D
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On the Main Level, conveyor CP Manufacturing, Inc. (Model: 9026630) was being cleaned, employees were inside the conveyor without locks being applied. This exposed employees to accidental / inadvertent restart of equipment.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) On the Main Level, conveyor CP Manufacturing, Inc. (Model: 9026630) toggle switches were used as an energy isolating device. This exposed employees to accidental / inadvertent restart of equipment. (b) The Sebright Products Inc. compactor (S/N: 11 08 10637) selector switch was used as an energy isolating device. This exposed employees to accidental / inadvertent restart of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.147 F03 II D
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: (a) On the Main Level; the CP Manufacturing, Inc. conveyor was being cleaned out by employees. Neither employee applied a personal lockout device before working on it. This exposed employees to accidental / inadvertent restart of equipment.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) In the Maintenance Area, the HydraPower hydraulic press brake used to bend various parts without guards. The hydraulic press brake was operated by foot pedal exposing employees to struck-by / caught-in hazards.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On the Main Level; the motor for conveyor labeled PNL MCC 1C CB13 M202 had damage on the top of the electrical box exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections in this industry (NAICS 562111)
CHESTERTOWN, MD—2026-07-15
WALLACE HENRY DISPOSAL, LLC
EDEN PRAIRIE, MN—2026-07-09
111566 - JUNK MASTERS LLC
TOA BAJA, PR—2026-07-09
CONSOLIDATED WASTE SERVICE LLC
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
SAN RAFAEL, CA—2026-07-08
RG ENVIRONMENTAL HOLDINGS INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339786212.