MEADVILLE, PA —
OSHA Inspection: DUSTY A. MATHENEY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUSTY A. MATHENEY in 829 MARKET STREET, MEADVILLE, PA 16335 (NAICS 238160). OSHA activity number 339787996.
Where did this inspection happen?
- Establishment
- DUSTY A. MATHENEY
- Site address
- 829 MARKET STREET
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 586 ARCH STREET, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) A.) Dusty A. Matheney dba Elite Roofing & Siding, on or about May 30, 2014 and times prior thereto: Employees were utilizing products including, but not limited to, Franklin WeatherMaster Caulk. The company has not developed a written hazard communication program.
Recent events (2)
- — I (S) $400
- — Z (S) $1200
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (Construction Reference: 1926.59) A.) Dusty A. Matheney dba Elite Roofing & Siding, on or about May 30, 2014 and times prior thereto: Employees were utilizing products including, but not limited to, Franklin WeatherMaster Caulk. The company did not have an MSDS on-site for the product.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) A.) Dusty A. Matheney dba Elite Roofing & Siding, on or about May 30, 2014 and times prior thereto: Employees were utilizing products including, but not limited to, Franklin WeatherMaster Caulk. Employees did not have hazard communication training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions. A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Employees walking on a lower roof were exposed to potential injury from bundles of shingles that had the potential to slide down from the upper roof and strike the employees below. The employees were provided with head protection, however the use of head protection was not utilized. B.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Safety glasses are provided and used for operations including, but not limited to, cutting and nail gun operations. Safety glasses were not being utilized by personnel who were tearing up shingles.
Recent events (2)
- — I (S) $500
- — Z (S) $1600
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Fire extinguishers are deployed and available for employee use on-site. Employees have not had training on the proper selection and use of portable fire extinguishers. A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Employees have not had training on the proper use, care, storage and limitations of personal protective equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, southwest side of the structure, on or about May 30, 2014 and times prior thereto: Employees performing roofing actvities, including but not limited to, deploying roofing materials, were exposed to a 7.4 feet fall hazard to a lower roof and 20.8 feet fall hazard to the ground below.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, southwest side of the structure, on or about May 30, 2014 and times prior thereto: Employees performing roofing activities, including but not limited to, deploying roofing materials, were exposed to a 13.4 feet fall hazard to the ground below. Employees were three feet from the edge of the roof and were not utilizing a means of method of fall protection, including, but not limited to, personal fall arrest, guardrails, warning lines, safety nets and/or a safety monitor.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Employees engaging in roofing activities including, but not limited to, removing shingles, installing shingles and taking materials to the roof of the structure, 13.4 feet above ground level did not have fall protection training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: An employee engaging in roofing activities including, but not limited to, removing shingles, 13.4 feet above ground level had fall protection training that was not certified in writing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B13
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, southwest side of the structure, on or about May 30, 2014 and times prior thereto: An employee on-site was accessing the upper roof of the structure from the lower roof of the structure via a Werner 6004, 4 ft non-conductive fiberglass ladder. The employee utilized the top step and top of the step ladder to gain access to the upper roof 7.4 feet above.
Recent events (2)
- — I (S) $800
- — Z (S) $1200
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, southwest side of the structure, on or about May 30, 2014 and times prior thereto: An employee on-site was accessing the upper roof of the structure from the lower roof of the structure via a Werner 6004, 4 ft non-conductive fiberglass ladder. The ladder was not three feet above the landing surface of the upper roof, provided with a grab bar, or otherwise secured from displacement. B.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, southwest side of the structure, on or about May 30, 2014 and times prior thereto: An employee on-site was accessing the lower roof of the structure from ground level via a Werner metal extension ladder. The ladder was not three feet above the landing surface of the lower roof, provided with a grab bar, or otherwise secured from displacement. The ladder was only extended two feet above the landing surface of the lower roof. C.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, northwest side of the structure, on or about May 30, 2014 and times prior thereto: An employee on-site was accessing the lower roof of the structure from ground level via a Werner D-1124-2 metal extension ladder. The ladder was not three feet above the landing surface of the lower roof, provided with a grab bar, or otherwise secured from displacement. The ladder was only extended two feet above the landing surface of the lower roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: Employees on-site utilize various ladders, including, but not limited to, Werner metal extension ladders and a Werner fiberglass step ladder. The employees have not had training on the proper setup and use of the step ladder and extension ladders.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.150 C01 VIII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: A.) Dusty A. Matheney dba Elite Roofing & Siding, 829 Market Street, Meadville, PA 16335, on or about May 30, 2014 and times prior thereto: A Badger 5 lb. dry chemical fire extinguisher (S/N: ZF-695724) that was deployed and available for use on-site. The last annual maintenance conducted on the fire extinguisher occurred in February 2013.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source