TAUNTON, MA —
OSHA Inspection: B&J MANUFACTURING CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of B&J MANUFACTURING CORPORATION in 55 CONSTITUTION DRIVE, TAUNTON, MA 02780 (NAICS 332999). OSHA activity number 339788010.
Where did this inspection happen?
- Establishment
- B&J MANUFACTURING CORPORATION
- Site address
- 55 CONSTITUTION DRIVE
- City
- TAUNTON
- State
- MA
- ZIP
- 02780
- Mailing
- 55 CONSTITUTION DRIVE, TAUNTON, MA 02780
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 33
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1400.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: Location: Buffing/Polishing Area Two employees working in the buffing/polishing department were exposed to noise levels above the Action Level of 85 dBA, and the employer had not developed or implemented a Hearing Conservation Program that included: 1) Training 2) Provision of annual audiometric tests 3) Performance of periodic noise surveys to determine if employees are being exposed above the PEL The employees were exposed to 8-hour time-weighted averages of: 1) Elias Giron: 87.8 dBA, or 73.7% Dose 2) Otilio Trejo: 90.2 dBA, or 103% Dose
Recent events (2)
- — I (S) $1400
- — Z (S) $3500
1910.126 E
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1120.00 Reduced
1440
General-duty citation text
29 CFR 1910.126(e): Cyanide tanks were not provided with a dike or other safeguard to prevent cyanide from mixing with an acid if the dip tank were to fail: Location: Plating Department Copper cyanide plating tank was not provided with a dike that would prevent any overspill from interacting with acid overflows and creating hydrogen cyanide gas.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Location: Worksite A work rest for a grinding machine was adjusted 1/2 an inch away from the wheel.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1120.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Location: Buffing/Polishing Department None of the shafts for the buffing and polishing machines, which were located approximately 4 feet off the ground, were protected by stationary casing or troughs.
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
More inspections at B&J MANUFACTURING CORPORATION
TAUNTON, MA—2014-07-11 00:00:00
B&J MANUFACTURING CORPORATION
TAUNTON, MA—2006-03-17 00:00:00
B&J MANUFACTURING CORPORATION
TAUNTON, MA—2002-10-02 00:00:00
B&J MANUFACTURING CORPORATION
TAUNTON, MA—1999-03-19 00:00:00
B&J MANUFACTURING CORPORATION
TAUNTON, MA—1996-03-21 00:00:00
B&J MANUFACTURING CORPORATION
View B&J MANUFACTURING CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339788010.