OSHA Inspection: WATERVIEW SITE SERVICES, LIMITED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WATERVIEW SITE SERVICES, LIMITED in 28 BERMUDA ROAD, WESTPORT, CT 06880 (NAICS 238140). OSHA activity number 339794109.

Watch Waterview Site Services, Limited — free Get an email when a new federal OSHA severe-injury report for Waterview Site Services, Limited is published. One employer, no account, unsubscribe in one click.
Site address
28 BERMUDA ROAD
City
WESTPORT
State
CT
ZIP
06880
Mailing
PO BOX 2509, WESTPORT, CT 06880
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.    Jobsite: Employees were working on a fabricated frame scaffold platform, which was not fully planked on each working level and exposed to a fall hazard.
Recent events (1)
  • — Z (S) $2000

1926.451 B05 II

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.    Jobsite: The ends of scaffold planks/platforms, from that the employees were working, extended over the supports far more than 18 inches, and no other safe means were utilized to prevent the planks/platforms from tipping.
Recent events (1)
  • — Z (S) $2000

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.    Jobsite:  The fabricated frame scaffold platform, from which employees were working at a height more than 18 feet above the ground was not equipped with appropriate and safe means of access.  On or about June 04, 2014, one of employees fell to the ground while attempting to climb down the frames of the scaffold and sustained serious injuries from the incident.
Recent events (1)
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  Jobsite:   The employees, working on the platforms of the fabricated metal frame and cantilevered end supported scaffolds were not protected from the fall hazards by the use of appropriate fall protection devices and/or systems.
Recent events (1)
  • — Z (S) $2000

1926.451 F03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  Jobsite: The employer did not ensure that the scaffolds and scaffold components were inspected by a competent person to prevent employees from fall and tipping hazards.
Recent events (1)
  • — Z (S) $2000

1926.454 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area.  Jobsite: The employer did not ensure that all employees who performed work from the scaffolds were trained by a qualified person in the procedures to control or minimize the hazards related to scaffold use.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339794109.