On , OSHA opened a complaint safety inspection of BURLINGTON FORD AND LINCOLN in 1975 ROSE AVE, BURLINGTON, CO 80807 (NAICS 441110). OSHA activity number 339794943.
Where did this inspection happen?
- Establishment
- BURLINGTON FORD AND LINCOLN
- Site address
- 1975 ROSE AVE
- City
- BURLINGTON
- State
- CO
- ZIP
- 80807
- Mailing
- 1975 ROSE AVE, BURLINGTON, CO 80807
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- Employees
- 12
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck-by hazards while using an automotive lift: (a) On or about June 3, 2014, and at times prior, the employer did not ensure that employees were safe from crushing and struck-by hazards while using the Challenger Versymmetric Lift, Model 39000, in that the automotive lift exhibited defects such as, but not limited to, swing arms on the left side that would inadvertently move while they were elevated, as well as uncharacteristic vibration and noise. Further, the employer required employees to regularly lift vehicles that exceeded the lift's rated weight capacity. Additionally, vehicles with frames that were too large for the lift were raised by the lift necessitating the employee's use of unrated, unlisted and uncertified wooden blocks on the lifting pads to increase the height of the contact points. (b) On or about June 3, 2014, and at times prior, the employer did not document that all lift users were trained to use the lifts. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2800
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: a) On or about June 3, 2014, and at times prior, the employer did not protect employees from slip hazards in the service shop next to the oil heater when water accumulates on the floor and used automotive oil is poured and mixes with the water to make the floor slippery. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1200
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) On or about June 3, 2014, and at times prior, the employer exposed employees to corrosive hazards where employees handle used vehicle batteries and chemicals such as ammonia. The employer did not provide suitable facilities for quick drenching or flushing eyes in the immediate work area for emergency use. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1600
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, and flange projections: (a) On or about June 3, 2014, the employer did not protect employees from rotating parts and flying debris in that the bench grinder in the auto shop was missing a guard over the side of the abrasive wheel. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1200
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) On or about June 3, 2014, the employer did not protect employees from caught-in hazards by ensuring that the bench grinder in the auto shop had a work rest. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): A safety guard for an abrasive wheel machine, where the operator stands in front of the machine, was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) On or about June 3, 2014, the employer did not protect employees from struck-by hazards by ensuring that the bench grinder in the auto shop had a tongue guard. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.303 B08 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted: (a) On or about June 3, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards from an electrical outlet between the oil change and detail bays that was susceptible to damage because it was held up by an unsupported 4 feet section of conduit rather than a secured object. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $1200
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about June 3, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards in that the electrical panels on the north and south walls in the oil change bay were blocked from access by cabinets and stored items. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about June 3, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards in that the electrical panels on the north wall in the oil change bay was missing its door and was missing three breakers. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.305 J02 V
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed): (a) On or about June 3, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards in that the three electrical outlets around the detail bay (one mounted from the floor between the detail bay and the oil change bay, two on the east wall of the detail bay) did not have covers to keep water out of them. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $400.00 · Current $400.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about June 3, 2014, and at times prior, the employer had developed a written hazard communication program which includes labeling, safety data sheets and training. In the work place employees encounter many chemicals including but not limited to, gasoline (flammable; carcinogen; target organs are the liver, kidneys, bladder, blood, bone marrow, nervous system), Clean Parts Spray Cabinet Detergent (corrosive), whitewall cleaner (irritant to skin, eyes, and digestive system), and ammonia (corrosive to eyes, skin and the respiratory system; target organs are lungs, upper respiratory tract, skin and eyes). Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $400
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) On or about June 3, 2014, the employer had not train employees on the new hazard communication information including the label elements, signal words and safety data sheets format, that was required to be completed by December 1, 2013. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 441110)
SAN ANTONIO, TX—2026-07-08
NORTH PARK TOYOTA OF SAN ANTONIO
BIRMINGHAM, MI—2026-06-29
SIGNATURE ASSOCIATES, LLC
SACRAMENTO, CA—2026-06-24
MAITA TOYOTA OF SACRAMENTO
PATEROS, WA—2026-06-22
WA317991601 - COLUMBIA RIVER AUTO SALES LLC
RAYMOND, WA—2026-06-18
WA317991734 - FIVE STAR DEALERSHIPS INC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339794943.