Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HUDSON ELEVATOR GROUP, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of HUDSON ELEVATOR GROUP, INC. in PS 313 45-45 42ND STREET, SUNNYSIDE, NY 11104 (NAICS 238290). OSHA activity number 339797201.

Watch Hudson Elevator Group, INC. — free Get an email when a new federal OSHA severe-injury report for Hudson Elevator Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
PS 313 45-45 42ND STREET
City
SUNNYSIDE
State
NY
ZIP
11104
Mailing
963 VAN DUZER STREET, STATEN ISLAND, NY 10304
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 A06

Deleted Serious Gravity 10 6 instances 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person:  (a) At the worksite - Elevator constructors working at floors 1-6 in an elevator shaft used single sheets of plywood over planking. Planking drawings designed by a qualified person required two sheets of plywood;  on or about 06/05/14.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1926.451 F03

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $5950.00
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:     (a) The elevator shaft, all levels - One layer of plywood was used for platforms on floors 1-6 in the elevator shaft.  Two layers were required; on or about 06/05/14.     NOTE:   IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $5950
  • — C (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5950.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    (a) Elevator shaft, fifth floor - An elevator constructor engaged in hoisting material was exposed to a fall hazard of over 50 feet;  on or about 06/05/14.     NOTE:   IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $ 1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • — J (S) $5950
  • — C (S) $7000
  • — Z (S) $7000

View HUDSON ELEVATOR GROUP, INC.'s full OSHA safety record →