PHILADELPHIA, PA —
OSHA Inspection: MASTERKEY CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MASTERKEY CONSTRUCTION in 2012 WEST GIRARD AVENUE, PHILADELPHIA, PA 19130 (NAICS 238130). OSHA activity number 339834863.
Where did this inspection happen?
- Establishment
- MASTERKEY CONSTRUCTION
- Site address
- 2012 WEST GIRARD AVENUE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19130
- Mailing
- 6831 ROOSEVELT BLVD, PHILADELPHIA, PA 19149
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Jobsite, 2012 West Girard Avenue, North Exit - Employees used a folded a-frame ladder that did not reach the landing surface 36 inches above the ground level, observed on or about 6/23/14.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards. a) Jobsite, 2012 West Girard Avenue - Employees were using a folded a-frame ladder with a 36 inch break in elevation without being trained in ladder and/or stairway safety on or about 6/23/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.150 C01 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet: a) Jobsite, 2012 West Girard Street - The employer did not provide a fire extinguisher on site during construction activities, observed on or about 6/23/14.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Jobsite, 2012 West Girard Avenue - Employees were performing carpentry operations within 3 feet of unprotected edges 24 feet above ground level without being trained in fall protection. Employees did not know the trigger height for fall protection in construction on or about 6/23/14.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $6160.00 · Current $4312.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Jobsite, 2012 West Girard Avenue - Employees were performing carpentry operations within 3 feet of unprotected edges 24 feet above ground level without conventional or alternative methods of fall protection, observed on or about 6/23/14. Masterkey Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 960212, citation number 1, item number 1 and was affirmed as a final order on 5/16/14, with respect to a workplace located at 1701 South Street Philadelphia, PA.
Recent events (2)
- — I (R) $4312
- — Z (R) $6160
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339834863.