GREENWICH, CT —
OSHA Inspection: STAMFORD FORGE LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STAMFORD FORGE LLC in 1059 NORTH STREET, GREENWICH, CT 06836 (NAICS 238120). OSHA activity number 339838476.
Where did this inspection happen?
- Establishment
- STAMFORD FORGE LLC
- Site address
- 1059 NORTH STREET
- City
- GREENWICH
- State
- CT
- ZIP
- 06836
- Mailing
- 32 LEON PLACE, STAMFORD, CT 06902
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1900.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing type injuries from inadequately supported steel "Tee" beam that was being prepared for welding: Worksite: The employer did not ensure through providing specific training, instruction and/or visual observation that the employee, performing tack-welding tasks to install "T" steel beams onto the existing "I" beams of a structure was performing the tasks safely and appropriately at all times to prevent the "T" beams from falling or displacement. On or about July 7, 2014, one of "T" beams displaced and fell soon after the forks used to support the beam lowered down due to insufficient welds done on one of ends of the beam. The employee was pinned in between the beam and a column and sustained serious injuries from the incident.
Recent events (2)
- — I (S) $1900
- — Z (S) $2800
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). WORKSITE: The employer did not ensure through providing training and evaluation that the employee, operating the CAT model 2C5000 forklift (PIT), serial number AT9032837, was competent to operate the PIT safely at all times.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
More inspections in this industry (NAICS 238120)
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
CHESAPEAKE, VA—2026-07-08
MODERN STEEL AND STAIR LLC
YAKIMA, WA—2026-07-07
WA317991949 - H & A STEEL ERECTORS LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source