Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURKE DIVIDE ELECTRIC COOPERATIVE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BURKE DIVIDE ELECTRIC COOPERATIVE in VACINITY OF HIGHWAY 8, SOUTH OF BOWBELLS, BOWBELLS, ND 58721 (NAICS 238210). OSHA activity number 339842338.

Watch Burke Divide Electric Cooperative — free Get an email when a new federal OSHA severe-injury report for Burke Divide Electric Cooperative is published. One employer, no account, unsubscribe in one click.
Site address
VACINITY OF HIGHWAY 8, SOUTH OF BOWBELLS
City
BOWBELLS
State
ND
ZIP
58721
Mailing
9549 HWY 5 WEST, COLUMBUS, ND 58727
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
40
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:     (a) On or about July 8, 2014, for the employees exposed to excavation cave-in hazards without a trained competent person on site while installing electrical lines in an unprotected trench approximately 7 feet deep in the vicinity of Highway 8, south of Bowbells, ND.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins and/or indications of failure of protective systems:   (a) On or about July 8, 2014, for the employees exposed to cave-in hazards while installing electrical lines in a trench approximately seven feet deep with unprotected vertical sidewalls and evidence of fissures/sloughing in the vicinity of Highway 8, south of Bowbells, ND.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:     (a) On or about July 8, 2014, for the employees exposed to cave-in hazards while installing electrical lines in an unprotected trench approximately seven feet deep in the vicinity of Highway 8, south of Bowbells, ND.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:     (a) On or about July 8, 2014, for the employees installing electrical lines in a trench approximately seven feet deep with unprotected vertical walls in the vicinity of Highway 8, south of Bowbells, ND.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339842338.