MCALLEN, TX —
OSHA Inspection: CEASAR TORRES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CEASAR TORRES in 3701 COLBATH, MCALLEN, TX 78501 (NAICS 238310). OSHA activity number 339844235.
Where did this inspection happen?
- Establishment
- CEASAR TORRES
- Site address
- 3701 COLBATH
- City
- MCALLEN
- State
- TX
- ZIP
- 78501
- Mailing
- 17108 QUEEN PALM, PENITAS, TX 78576
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 A06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person: At this location, employees were using a scaffold, which was not designed by a qualified person, to install foam insulation along a building wall.
Recent events (1)
- — Z (S) $2000
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. At this location, employees installed insulation foam to a wall from a scaffold, greater than 10 feet, and had to climb the scaffold planks and support structure to reach the top.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: At this location, employees installing foam insulation to a building wall were using a scaffold, greater than 10 feet, and were not provided fall protection.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238310)
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339844235.