COLORADO SPRINGS, CO —
OSHA Inspection: LOYA ROOFING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOYA ROOFING, LLC. in 1418 N. TEJON STREET, COLORADO SPRINGS, CO 80903 (NAICS 238160). OSHA activity number 339846594.
Where did this inspection happen?
- Establishment
- LOYA ROOFING, LLC.
- Site address
- 1418 N. TEJON STREET
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80903
- Mailing
- 7165 WHITE MOUNTAIN RD, COLORADO SPRINGS, CO 80915
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: (a) On or about July 7, 2014, Loya Roofing, LLC., did not ensure that its employees were protected from falls while working at heights greater than 6 feet. Employees of Loya Roofing, LLC. were exposed to fall hazards in excess of 11.5 feet while engaged in roofing activities on the roof of a residential building with no fall protection in place. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: (a) On or about July 7, 2014, Loya Roofing, LLC., did not ensure that portable ladders, used to access upper landing surfaces, extend at least 3 feet above the upper landing surface to which the ladders were used to gain access. Workers were observed using a ladder to access the roof of a residential building. Ladder did not extend at least 3 ft above the landing platform and was not tied to the roof edge. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: (a) On or about July 7, 2014, Loya Roofing, LLC., did not ensure that ladders were secured and used on surfaces that were stable and leveled. Employees used an extension ladder to access the top roof of a two story house, ladder was standing on an uneven stack of roofing materials and was not secured, exposing employees to fall hazards in excess of 11 feet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B22
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: (a) On or about July 7, 2014, Loya Roofing, LLC., did not ensure that employees using ladders were not carrying objects or loads that could cause the employee to lose balance and fall. An employee used an extension ladder to access the top roof of a two story house while using a cellular phone, exposing the employee to fall hazards in excess of 11 feet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: (a) On or about July 7, 2014, Loya Roofing, LLC., did not ensure that employees using ladders were trained in the procedures to be followed in order to minimize hazards related to ladders. Employees were exposed to fall hazards in excess of 11 feet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at LOYA ROOFING, LLC.
COLORADO SPRINGS, CO—2019-03-20 00:00:00
LOYA ROOFING, LLC
View LOYA ROOFING, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source