WORCESTER, MA —
OSHA Inspection: GUIGLI CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GUIGLI CORPORATION in WORCESTER STATE UNIVERSITY 486 CHANDLER STREET, WORCESTER, MA 01602 (NAICS 238910). OSHA activity number 339847105.
Where did this inspection happen?
- Establishment
- GUIGLI CORPORATION
- Site address
- WORCESTER STATE UNIVERSITY 486 CHANDLER STREET
- City
- WORCESTER
- State
- MA
- ZIP
- 01602
- Mailing
- 10 TECH CIRCLE, NATICK, MA 01760
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 40
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.602 A04
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.602(a)(4): Brake systems for self-propelled rubber-tired off-highway equipment manufactured after January 1, 1972 did not meet the applicable minimum performance criteria set forth in the following Society of Automotive Engineers Recommended SAE J237-1971. Caterpillar 966E, SN Y9905454; The brakes on Caterpillar 966E, SN Y9905454, failed and the machine rolled down the hill at Worcester State University by the football field.
Recent events (2)
- — I (O) $2100
- — Z (S) $4200
1926.602 C01 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(i): Lifting and hauling equipment did not have the rated capacity clearly posted on the vehicle so as to be clearly visible to the operator: Worcester State University, CAT 966E, SN 99Y05454; There was no load chart on the equipment to ensure that the lifting capacity of the equipment was not exceeded.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.602 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval: Worcester State University, CAT 966E, SN 99Y05454; The employer used the bucket of a front end loader as a hoisting device by attaching a chain with hooks to the bucket in lieu of using a bucket with an anchor point.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.602 C01 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.602(c)(1)(iv): Steering or spinner knobs were attached to the steering wheel of earth moving equipment. Caterpillar, 966E Front End Loader, SN 99Y05454; Spinner knob was attached to the steering wheel affecting the safe operation of the front end loader.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at GUIGLI CORPORATION
NORWOOD, MA—2024-02-27 00:00:00
GUIGLI CORPORATION
RANDOLPH, MA—2023-11-07 00:00:00
GUIGLI CORPORATION
WORCESTER, MA—2020-06-17 00:00:00
GUIGLI CORPORATION
View GUIGLI CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339847105.