Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAXX BUILT, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAXX BUILT, LLC in 511 KENYON ST., N.W., WASHINGTON, DC 20009 (NAICS 236118). OSHA activity number 339849374.

Watch Jaxx Built, LLC — free Get an email when a new federal OSHA severe-injury report for Jaxx Built, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JAXX BUILT, LLC
Site address
511 KENYON ST., N.W.
City
WASHINGTON
State
DC
ZIP
20009
Mailing
223 PENNY LANE, STERLING, VA 20164
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 5 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)       First Floor - On or about 07/14/2014, workers renovating a row home were exposed to a 9 foot fall from a 5 foot by 7 foot wall opening which had not been provided with fall protection.       b)      Third Floor - On or about 07/14/2014, workers renovating a row home were exposed to a 30 foot fall from a 5 foot by 7 foot wall opening which had not been provided with fall protection.       c)       Second Floor  On or about 07/14/2014, workers renovating a row home were exposed to a 10 foot fall through a 3.5 foot wide by 20 foot long unguarded floor hole.       d)       Third Floor  On or about 07/14/2014, workers renovating a row home were exposed to a 20 foot fall through a 3.5 wide foot by 20 foot  long unguarded floor hole.       e)      Front Porch  On or about 07/14/2014, workers renovating a row home were exposed to a 8 foot fall from the open side of a concrete porch.     Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a)  Porch - On or about 07/14/2014, workers were exposed to a 4 foot fall hazard from a job-made ladder that projected only 18 in. above the ladder landing.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.404 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:   a)  Job Site - On or about 07/14/2014, workers using portable electric power tools, including, but not limited to, circular and reciprocating saws, were not provided with either ground fault circuit interrupters or an assured equipment grounding conductor program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

MACY'S