IDAHO FALLS, ID —
OSHA Inspection: WILBUR-ELLIS FEED DIVISION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WILBUR-ELLIS FEED DIVISION in 2800 SOUTH MILLIGAN ROAD, IDAHO FALLS, ID 83402 (NAICS 311211). OSHA activity number 339852568.
Where did this inspection happen?
- Establishment
- WILBUR-ELLIS FEED DIVISION
- Site address
- 2800 SOUTH MILLIGAN ROAD
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83402
- Mailing
- 2800 SOUTH MILLIGAN ROAD, IDAHO FALLS, ID 83402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311211
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4250.00 · Current $2125.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Receiving Area: On or about 7-16-2014, the intake grate bars were damaged and spread apart, not adequately guarding the intake auger from possible contact. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $2125
- — Z (S) $4250
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1275.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Receiving Area: On or about 7-16-2014, the lower leg drive shaft extended more than 1/2 it's diameter and was not protected by a non-rotating guard. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1275.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Warehouse: On or about 7-16-2014, the 115 volt electrical control panel cover for the pallet wrapping machine was not effectively closed due to a broken latch, allowing employee exposure to unguarded live parts. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1275
- — Z (S) $2550
More inspections in this industry (NAICS 311211)
KANSAS CITY, KS—2026-06-17
GRAIN CRAFT - KANSAS CITY
RICHLAND, WA—2026-06-10
WA317991603 - GF BLENDS INC
LITTLEFIELD, TX—2026-06-02
CONTINENTAL DAIRY FACILITIES SOUTHWEST, LLC
CAMBRIA, WI—2026-05-08
DIDION MILLING, INC.
HASTINGS, MN—2026-04-22
111116 - ARDENT MILLS LLC
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339852568.