OSHA Inspection: DAVID GENERAL CONTRACTING, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAVID GENERAL CONTRACTING, INC in 4315 BRONXWOOD AVE, BRONX, NY 10461 (NAICS 238160). OSHA activity number 339855124.

Watch David General Contracting, INC — free Get an email when a new federal OSHA severe-injury report for David General Contracting, INC is published. One employer, no account, unsubscribe in one click.
Site address
4315 BRONXWOOD AVE
City
BRONX
State
NY
ZIP
10461
Mailing
84 SUNNYSIDE LANE, WESTBURY, NY 11590
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 7 instances 7 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  On or about 7/17/2014, Bronxwood Ave.  a) The employees were not provided safety and health training as required by the standard.
Recent events (1)
  • — Z (S) $1600

1926.252 A

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.252(a): Whenever materials are dropped more than 20 feet to any point lying outside the exterior walls of the building, an enclosed chute of wood, or equivalent material, was not used. For the purpose of this paragraph, an enclosed chute is a slide, closed in on all sides, through which material is moved from a high place to a lower one:  On or about 7/17/2014, Bronxwood Ave.  a) The employees were not using a chute to contain the roof debris.
Recent events (1)
  • — Z (S) $1600

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:  On or about 7/17/2014, Bronxwood Ave.  a) The extension cord was used by the employees to energize their power tools. The cord had the ground pin broken off.
Recent events (1)
  • — Z (S) $1600

1926.501 B11

Serious Gravity 10 4 instances 4 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toe boards, safety net systems, or personal fall arrest systems:  On or about 7/17/2014, Bronxwood Ave.  a) There were four employees working on the roof, approximately 24' high without fall protection.
Recent events (1)
  • — Z (S) $2800

1926.1053 B08

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(8): Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, was not secured to prevent accidental displacement, or a barricade was not used to keep the activities or traffic away from the ladder:  On or about 7/17/2014, Bronxwood Ave.  a) The employees used the 29' aluminum extension ladder which was placed in the driveway and not secured.
Recent events (1)
  • — Z (S) $2000

1926.1053 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:  On or about 7/17/2014, Bronxwood Ave.  The area at the base of the ladder had debris such as shingles, a tarp, wood and an extension cord causing a tripping hazard.
Recent events (1)
  • — Z (S) $1600

1926.1053 B15

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use:  On or about 7/17/2014, Bronxwood Ave.  a) The employee used a metal scraper to replace a missing rung on the extension ladder.