OSHA Inspection: MCCOY'S BUILDING SUPPLY #70

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MCCOY'S BUILDING SUPPLY #70 in 110 WONDER WORLD DRIVE, SAN MARCOS, TX 78666 (NAICS 444110). OSHA activity number 339862948.

Watch Mccoy'S Building Supply #70 — free Get an email when a new federal OSHA severe-injury report for Mccoy'S Building Supply #70 is published. One employer, no account, unsubscribe in one click.
Site address
110 WONDER WORLD DRIVE
City
SAN MARCOS
State
TX
ZIP
78666
Mailing
1350 IH-35 NORTH, SAN MARCOS, TX 78666
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
23
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3300.00 · Current $3300.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    On or about 22 July 2014, and at times prior thereto, a door in the Bulk Feed Room was not clearly identified as an Exit, exposing the employees in the area to a fire hazard.
Recent events (2)
  • — I (O) $3300
  • — Z (S) $3300

1910.157 C01

Other-than-serious 3 instances 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    On or about 22 July 2014, and at times prior thereto, three fire extinguishers were not clearly marked or identified so that they could be readily accessible to employees, exposing the employees in the area to a fire hazard.  1) The extinguisher located in the Bulk Feed Room was not identified with a sign.  2) The extinguisher located at the Contractor Entrance was not identified with a sign.  3) The extinguisher located inside the Breaker Room was not identified with a sign.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 I A

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $2750.00 Reduced
29 CFR 1910.303(g)(1)(i)(A): The depth of the working space in the direction of access to live parts was less than indicated in Table S-1, or 36 inches for 600 volts, nominal, or less. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed.    On or about 22 July 2014, and at times prior thereto, electrical panels were blocked by various items in front, exposing employees to an electrical shock hazard.  1) Two electrical breaker panels, a knife switch, and a transformer located in the southwest corner of the warehouse were blocked for access by various items.  2) Two electrical panels located near the lumber yard office were blocked for access by various items.
Recent events (2)
  • — I (S) $2750
  • — Z (S) $5500

1910.303 G01 II

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.  On or about 22 July 2014, and at times prior thereto, electrical panels had various items stored next to and underneath, exposing employees to an electrical shock hazard. 1) Two electrical breaker panels, a knife switch, and a transformer located in the southwest corner of the warehouse had various items stored next to or underneath. 2) Two electrical panels located near the lumber yard office had various items stored next to or underneath.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $2750.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.    On or about 22 July 2014, and at times prior thereto, an energized four-plug electrical circuit outlet box did not have the faceplate mounted, exposing the employees using the outlet to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (O) $2750
  • — Z (S) $5500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339862948.