PEEKSKILL, NY —
OSHA Inspection: JMO CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of JMO CONSTRUCTION, INC. in 836 WASHINGTON STREET, PEEKSKILL, NY 10566 (NAICS 238160). OSHA activity number 339865008.
Where did this inspection happen?
- Establishment
- JMO CONSTRUCTION, INC.
- Site address
- 836 WASHINGTON STREET
- City
- PEEKSKILL
- State
- NY
- ZIP
- 10566
- Mailing
- 110 WOODCREST AVE., WHITE PLAINS, NY 10603
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury: On or about 7/23/2014, Washington Street a) The employees were not provided safety and health training as required by the standard.
Recent events (1)
- — Z (S) $1600
1926.501 B01
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 7/23/2014, Washington Street a) The employees worked on the roof and did not have fall protection.
Recent events (1)
- — Z (S) $2000
1926.1053 B16
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not immediately marked in a manner that readily identifies them as defective, or were tagged with "Do Not Use" or similar language, and was not withdrawn from service until repaired: On or about 7/23/2014, Washington Street a) The employees used the aluminum ladder to gain access to/from the roof. A couple of the lower rungs were dented.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source