Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TIFFIN DOOR COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TIFFIN DOOR COMPANY, INC. in 6339 HIGHWAY 19, VINA, AL 35593 (NAICS 337110). OSHA activity number 339868291.

Watch Tiffin Door Company, INC. — free Get an email when a new federal OSHA severe-injury report for Tiffin Door Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6339 HIGHWAY 19
City
VINA
State
AL
ZIP
35593
Mailing
P.O. BOX 310, RED BAY, AL 35582
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.157 C01

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   (a) On or about 07/23/14 - Outside the paint booth, fire extinguisher was blocked by materials such as used 5 gallon paint buckets.     (b) On or about 07/23/14 - Rails and Stiles area, fire extinguisher was blocked by materials such as pallets of wood.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.242 B

Serious Gravity 5 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $3570.00 · Current $2142.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   (a)  On or about 07/23/14 -  Paint Booth area, compressed air was used with an output of 87 p.s.i. to clean off parts.   (b)  On or about 07/23/14 -  Coping saw, compressed air was used with an output of 85 p.s.i. to clean off parts.  (c)  On or about 07/23/14 -  Time saver 1100, compressed air was used with an output of 86 p.s.i. to clean off parts.   (d)  On or about 07/23/14 -  DA Sanding area, compressed air was used with an output of 92 p.s.i. to clean off parts.   (e)  On or about 07/23/14 -  Cefla finishing machine, compressed air was used with an output of 95 p.s.i. to clean off parts.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3570

1910.303 G02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:    (a)  On or about 07/23/14 - Hand Sanding, employees were exposed to the hazards of electrical shock from exposed electrical parts.  A 110-volt light switch encased in a metal protective box was damaged, exposing the neutral and ground wires.  (b)  On or about 07/23/14 - Hand Sanding, employees were exposed to the hazards of electrical shock from exposed electrical parts.  A 240-volt fuse box encased in a metal protective box was open, exposing the hot, neutral and ground wires and the fuses.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.304 F01 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:    (a)  On or about 07/23/14 -  Timesaver 2300 area, an electrical disconnect panel was blocked by boxes and material.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339868291.