NORTH RICHLAND HILLS, TX —
OSHA Inspection: HUTCHERSON CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HUTCHERSON CONSTRUCTION, INC. in 8541 DAVIS BLVD, NORTH RICHLAND HILLS, TX 76182 (NAICS 236220). OSHA activity number 339877375.
Where did this inspection happen?
- Establishment
- HUTCHERSON CONSTRUCTION, INC.
- Site address
- 8541 DAVIS BLVD
- City
- NORTH RICHLAND HILLS
- State
- TX
- ZIP
- 76182
- Mailing
- 1020 HARRISON AVENUE, ARLINGTON, TX 76011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 16
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.20 B02
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): On or about July 31, 2014, at a commercial steel erection project, the site Project Superintendent directing the work did not ensure that he and the workers engaged in welding activities were protected from unprotected fall hazards: a) where there was a break in elevation of 19 inches from the second story landing to the upper landing surface; b) guard rails were not installed on the second story landing; c) mid-rails were not installed on the top upper landing area; and d) workers worked outside of the guardrails hanging on by one hand and welding.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.760 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: On or about July 31, 2014, an employee on the rooftop of a steel erection construction project working with a grinder marking welding points and performing grinding work was not protected from fall hazards. The employee was exposed to a fall hazard of more than (6) feet to the ground below.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1051 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: On or about July 31, 2014, at a steel erection construction project, an employee performing grinding work was not provided with a stairway or ladder where there was a break in elevation of approximately 4 feet from the awning to the roof top exposing the employee to fall hazards.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339877375.