MOOREFIELD, WV —
OSHA Inspection: PILGRIM'S CORP.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PILGRIM'S CORP. in 214 SOUTH MAIN STREET, MOOREFIELD, WV 26836 (NAICS 311615). OSHA activity number 339878498.
Where did this inspection happen?
- Establishment
- PILGRIM'S CORP.
- Site address
- 214 SOUTH MAIN STREET
- City
- MOOREFIELD
- State
- WV
- ZIP
- 26836
- Mailing
- 214 SOUTH MAIN STREET, MOOREFIELD, WV 26836
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 600
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.119 D03 II
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: (a) Machine Rooms: The employer did not document in the process safety information (PSI) that the ammonia detection system complies with recognized and generally accepted good engineering practices. The PSI did not include the alarm settings and at what alarm setting emergency ventilation is activated, as determined on July 29, 2014. Abatement Certification Required for this Item.
Recent events (2)
- — I (S) $0
- — Z (S) $2550
1910.119 L04
- Issued
- Penalty
- Initial $2550.00 · Current $2550.00
General-duty citation text
29 CFR 1910.119(l)(4): A change covered by 29 CFR 1910.119(l) resulted in a change in the process safety information required by 29 CFR 1910.119(d) and the process information was not updated: (a) System #2: The employer conducted a management of change (MOC # 2014-MOP-07) to replace the oil pot on the #4 recirculator (R-4-OP). The employer did not update the process safety information, including the process and instrumentation diagrams (P&IDs), valve list, and equipment list prior to putting the oil pot into service, as determined on July 29, 2014.
Recent events (2)
- — I (O) $2550
- — Z (S) $2550
More inspections in this industry (NAICS 311615)
LEWISTON WOODVILLE, NC—2026-07-10
161527 - PERDUE FARMS INC
TIMBERVILLE, VA—2026-07-08
PILGRIMS PRIDE CORPORATION
WYOMING, MI—2026-07-06
MICHIGAN TURKEY PRODUCERS
COLD SPRING, MN—2026-06-25
111475 - PILGRIMS PRIDE CORPORATION
FRESNO, CA—2026-06-22
FOSTER POULTRY FARMS, LLC
More inspections in WV
NEW MARTINSVILLE, WV—2026-07-08
QUINET'S RESTAURANT
PARKERSBURG, WV—2026-07-07
PEOPLES CARTAGE INC
PROCTOR, WV—2026-07-06
COVESTRO LLC
PARSONS, WV—2026-07-01
A.L.L. CONSTRUCTION, INC.
HUNTINGTON, WV—2026-06-30
CINDY FLORES CONSTRUCTION, LLC
Source