Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CAT CONSULTING SERVICE, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAT CONSULTING SERVICE, LLC. in 5516, 5520 4TH STREET NE, WASHINGTON, DC 20011 (NAICS 236117). OSHA activity number 339881609.

Watch CAT Consulting Service, LLC. — free Get an email when a new federal OSHA severe-injury report for CAT Consulting Service, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
5516, 5520 4TH STREET NE
City
WASHINGTON
State
DC
ZIP
20011
Mailing
537 RANDOLPH STREET NW, WASHINGTON, DC 20011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236117
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:  a) Outside Front Yard Area of Structure - Workers were using a 10" blade portable table saw without its guard, on or about 08/04/2014.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Top Front Left Side of Roof - Workers were on the top level of the structure laying the plywood sub-floor, roof, not protected from falling 25 feet to the scrap materials and ground below, on or about 08/04/2014.  b) Left Side First Level Entrance - 12" wide ramp used to enter and exit the structure did not have guardrails, exposing workers to a 6 foot fall off the side of the ramp on or about 08/04/14.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $2800

MACY'S