OSHA Inspection: JORDAN POINT MARINE SERVICE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JORDAN POINT MARINE SERVICE, INC. in 109 JORDAN POINT RD., HOPEWELL, VA 23860 (NAICS 336612). OSHA activity number 339882995.

Watch Jordan Point Marine Service, INC. — free Get an email when a new federal OSHA severe-injury report for Jordan Point Marine Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
109 JORDAN POINT RD.
City
HOPEWELL
State
VA
ZIP
23860
Mailing
109 JORDAN POINT RD., HOPEWELL, VA 23860
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.253 E03 II C 3

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $884.00 Reduced
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system:    a.)    Jordan Point Marine Service: On or about 08/04/14, an oxygen and acetylene rig for heating parts was not provided with a flashback protective device in-line of the acetylene gas, as a result employees were potentially exposed to severe burns.     Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $884
  • — Z (S) $1360

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $884.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    a.)    Jordan Point Marine Service: On or about 08/05/14, a cover was not provided over the live conductor wires of a 120 volts wall recessed electrical outlet thereby exposed an employee to a potential shock hazard.     Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $884
  • — Z (S) $1360

1910.1200 H03 IV

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazardous communication program developed by the employer, including an explanation of labels received on shipped containers and the work place labeling system used by their employer, and the safety data sheet, including the order of information and how the employees can obtain and use the appropriate hazard information:    a.)      Jordan Point Marine Service: On or about 08/05/14, the employer did not train employees that use Gel-Kote, Micron CSC Black Antifouling and other hazardous chemicals in the workplace on the new labels received on shipped containers and safety data sheets.       Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JORDAN POINT MARINE SERVICE, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339882995.