HOPEWELL, VA —
OSHA Inspection: JORDAN POINT MARINE SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JORDAN POINT MARINE SERVICE, INC. in 109 JORDAN POINT RD., HOPEWELL, VA 23860 (NAICS 336612). OSHA activity number 339882995.
Where did this inspection happen?
- Establishment
- JORDAN POINT MARINE SERVICE, INC.
- Site address
- 109 JORDAN POINT RD.
- City
- HOPEWELL
- State
- VA
- ZIP
- 23860
- Mailing
- 109 JORDAN POINT RD., HOPEWELL, VA 23860
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 E03 II C 3
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $884.00 Reduced
General-duty citation text
29 CFR 1910.253(e)(3)(ii)(C)(3): Flashback protection was not provided by an approved device that would prevent flame from passing into the fuel gas system: a.) Jordan Point Marine Service: On or about 08/04/14, an oxygen and acetylene rig for heating parts was not provided with a flashback protective device in-line of the acetylene gas, as a result employees were potentially exposed to severe burns. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $884
- — Z (S) $1360
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $884.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a.) Jordan Point Marine Service: On or about 08/05/14, a cover was not provided over the live conductor wires of a 120 volts wall recessed electrical outlet thereby exposed an employee to a potential shock hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $884
- — Z (S) $1360
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazardous communication program developed by the employer, including an explanation of labels received on shipped containers and the work place labeling system used by their employer, and the safety data sheet, including the order of information and how the employees can obtain and use the appropriate hazard information: a.) Jordan Point Marine Service: On or about 08/05/14, the employer did not train employees that use Gel-Kote, Micron CSC Black Antifouling and other hazardous chemicals in the workplace on the new labels received on shipped containers and safety data sheets. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at JORDAN POINT MARINE SERVICE, INC.
HOPEWELL, VA—2010-04-29 00:00:00
JORDAN POINT MARINE SERVICE, INC.
HOPEWELL, VA—2006-01-01 00:00:00
JORDAN POINT MARINE SERVICE, INC.
HOPEWELL, VA—2001-03-29 00:00:00
JORDAN POINT MARINE SERVICE, INC.
View JORDAN POINT MARINE SERVICE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336612)
CLANTON, AL—2026-07-13
UBIQUE TECHNOLOGIES, INC.
POST FALLS, ID—2026-06-23
BURLY PRODUCTS
TACOMA, WA—2026-06-18
WA317991721 - SILVERBACK INDUSTRIES LLC
CATAUMET, MA—2026-06-16
BALLENTINE'S BOAT SHOP, INC.
PORT TOWNSEND, WA—2026-06-11
WA317991653 - ARMSTRONG CONSOLIDATED LLC
More inspections in VA
VIRGINIA BEACH, VA—2026-07-16
GRAND SLAM CAR WASH
KILMARNOCK, VA—2026-07-16
CARR'S TIRE SERVICE
COLLINSVILLE, VA—2026-07-16
ACES, LLC
PORTSMOUTH, VA—2026-07-15
DACS INC
MANASSAS, VA—2026-07-15
VAFMC LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339882995.