CHICAGO, IL —
OSHA Inspection: THE RELIABLE TUCKPOINTING CO.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE RELIABLE TUCKPOINTING CO. in 3520 N. LAKE SHORE DRIVE, CHICAGO, IL 60657 (NAICS 238140). OSHA activity number 339886350.
Where did this inspection happen?
- Establishment
- THE RELIABLE TUCKPOINTING CO.
- Site address
- 3520 N. LAKE SHORE DRIVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60657
- Mailing
- 7460 N. NATCHEZ AVE., NILES, IL 60714
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 40
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 D02
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2975.00
General-duty citation text
29 CFR 1926.451(d)(2): Suspension scaffold outrigger beams, when used, were not restrained to prevent movement: a) Suspension scaffold provided for employee use was equipped with an outrigger beam that was not restrained to prevent movement. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $2975
1926.451 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(d)(4)(i): Suspension scaffold outrigger beams were not set and maintained with the web in a vertical position: a) The web of an outrigger beam on a suspension scaffold provided for employee use was not maintained in a vertical position. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339886350.