ERIE, PA —
OSHA Inspection: THORP-PATTERSON CONSTRUCTION AND MANAGEMENT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THORP-PATTERSON CONSTRUCTION AND MANAGEMENT, LLC in 135 EAST 6TH STREET, ERIE, PA 16501 (NAICS 236220). OSHA activity number 339892291.
Where did this inspection happen?
- Establishment
- THORP-PATTERSON CONSTRUCTION AND MANAGEMENT, LLC
- Site address
- 135 EAST 6TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16501
- Mailing
- 1603 ASBURY ROAD, ERIE, PA 16505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) Thorp-Patterson Construction and Management, LLC / 135 East 6th Street, Erie PA: On or about July 31, 2014 individuals were working on a roof with approximately a 16 foot ground to eave height without using any fall protection.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1080.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Thorp-Patterson Construction and Management LLC / 135 East 6th Street, Erie, PA: On or about July 31, 2014 individuals were using a ladder to access the roof with an eave height of approximately 16 feet from ground level. The ladder was extended approximately 2 feet above the landing zone.
Recent events (2)
- — I (S) $1080
- — Z (S) $1600
More inspections in this industry (NAICS 236220)
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
SIOUX FALLS, SD—2026-07-13
REM CONSTRUCTION SERVICES, LLC
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
SIOUX FALLS, SD—2026-07-10
HENRY CARLSON COMPANY
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339892291.