Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: FR DEVELOPMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FR DEVELOPMENT in 532 CAJETAN ST., FORT COLLINS, CO 80524 (NAICS 236116). OSHA activity number 339893356.

Watch FR Development — free Get an email when a new federal OSHA severe-injury report for FR Development is published. One employer, no account, unsubscribe in one click.
Establishment
FR DEVELOPMENT
Site address
532 CAJETAN ST.
City
FORT COLLINS
State
CO
ZIP
80524
Mailing
345 E. MOUNTAIN AVE., FORT COLLINS, CO 80524
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety nets systems, or personal fall arrest system, nor was an alternative fall protection measure provided:   (a)          Junior & Senior Builders at 532 Cajetan St., Fort Collins, CO 80524:  On and before 7/23/14, the employer did not ensure that fall protection systems were utilized by employees engaged in framing activities while working on a 2 story residential new build. This condition exposed employee to fall hazards of approximately 10 feet.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1926.502 B11

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1926.502(b)(11): When guardrail systems are used at holes, they shall be erected on all unprotected sides or edges of the hole.  (a)          FR Development at 532 Cajetan St., Fort Collins, CO 80524:  On and before 7/23/14, the employer did not provide and install guardrail systems while employees engaged in framing activities around unprotected hole. The guardrail was missing around the access to the basement. This condition exposed employee to fall hazards of approximately 9 feet.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339893356.