WASHINGTON, DC —
OSHA Inspection: JVP CONTRACTORS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JVP CONTRACTORS, INC. in 5057 D ST., SE, WASHINGTON, DC 20032 (NAICS 238140). OSHA activity number 339907263.
Where did this inspection happen?
- Establishment
- JVP CONTRACTORS, INC.
- Site address
- 5057 D ST., SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20032
- Mailing
- 10522 TWIN CEDAR CT., LAUREL, MD 20723
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines carrying from 300 volts to 50 kv were less than 10 feet: a) Front of House - On or about 08/08/2014, workers installing stucco from the platforms of a fabricated frame scaffold were exposed to a 4 kv electrical contact hazards for portions of the metal scaffold were located within 4 inches and 11 inches of unshielded over-head power lines. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2800
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) Front of House - On or about 08/08/2014, a 30 ft. high fabricated frame scaffold was erected under the supervision of this companys site foremen and that scaffold was erected within 4 inches of 4 kv over-head power lines and which was not provided with fall protection while occupied by workers installing stucco on the front of a house under construction. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers: a) Front of House - On or about 08/08/2014, fall protection was not provided to three stucco mechanics who were exposed to a 24 foot fall hazard from the unguarded platform of a fabricated frame scaffold. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.
Recent events (1)
- — Z (S) $2000
More inspections at JVP CONTRACTORS, INC.
TOWSON, MD—2007-05-15 00:00:00
JVP CONTRACTORS, INC.
View JVP CONTRACTORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339907263.