Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE DE-JESUS, ROSTRO DIAZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE DE-JESUS, ROSTRO DIAZ in 4890 WILSHIRE CROSSING, CUMMING, GA 30040 (NAICS 238130). OSHA activity number 339909541.

Watch Jose De-Jesus, Rostro Diaz — free Get an email when a new federal OSHA severe-injury report for Jose De-Jesus, Rostro Diaz is published. One employer, no account, unsubscribe in one click.
Site address
4890 WILSHIRE CROSSING
City
CUMMING
State
GA
ZIP
30040
Mailing
3514 MORNING SIDE VILLAGE LN. APT. D, DORAVILLE, GA 30340
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):     On or about at 08/20/14 located at 4890 Wilshire Crossing, Cumming, GA:  The employer did not perform frequent and regular inspections where employees were installing floor joist on the 2nd floor without fall protection, no safety glasses and the air compressor wire box was missing the cover with the wires hanging out.
Recent events (1)
  • — Z (S) $2000

1926.102 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  On or about at 08/20/14 located at 4890 Wilshire Crossing, Cumming, GA:  Employees were observed using a pneumatic nail gun without safety glasses.
Recent events (1)
  • — Z (S) $2800

1926.405 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:  On or about at 08/20/14 located at 4890 Wilshire Crossing, Cumming, GA:  Employees were observed using a portable air compressor and the junction box cover was missing and the wires were hanging out.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a)  NOTE TO CSHO: USE THIS OPTION ONLY IN CASES WHERE THE INFEASIBILITY/GREATER HAZARD EXCEPTION IS NOT IN ISSUE.   On or about at 08/20/14 located at 4890 Wilshire Crossing, Cumming, GA:  The employer failed to provide personal fall protection for employees that were exposed to fall hazards of up to 10.2 feet while framing the house.
Recent events (1)
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339909541.