SOMERVILLE, MA —
OSHA Inspection: JAMES ENWRIGHT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JAMES ENWRIGHT in 595 SOMERVILLE AVENUE, SOMERVILLE, MA 02143 (NAICS 238130). OSHA activity number 339914970.
Where did this inspection happen?
- Establishment
- JAMES ENWRIGHT
- Site address
- 595 SOMERVILLE AVENUE
- City
- SOMERVILLE
- State
- MA
- ZIP
- 02143
- Mailing
- 32 MILLS DRIVE, DRACUT, MA 01826
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B05 II
- Issued
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was working from a pump jack scaffold whose platform extended greater than 18 inches over its support.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.451 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was working from a pump jack scaffold that did not bear on mudsills.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings shall be level, plumb, rigid, and capable of supporting the loaded scaffold without settling or displacement. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was working from a pump jack scaffold, the pump jack poles were not plumb.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E08
- Issued
- Penalty
- Initial $0.00 · Current $1000.00
General-duty citation text
29 CFR 1926.451(e)(8): Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was accessing a pump jack scaffold that was greater that 14 inches away from the horizontal surface.
Recent events (2)
- — I (S) $1000
- — Z (S) $0
1926.451 G01
- Issued
- Penalty
- Initial $2800.00 · Current $2150.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee working from a pump jack scaffold that was greater than ten feet above a lower level was not protected from falling to the ground below.
Recent events (2)
- — I (S) $2150
- — Z (S) $2800
1926.452 J02
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was working from a pump jack scaffold whose poles were not secured at the base to prevent unintentional displacement.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.501 B01
- Issued
- Penalty
- Initial $2800.00 · Current $2150.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location - 595 Somerville Avenue, Somerville, MA: On or about 8/21/2014, an employee was not protected from falling while installing sheathing from a balcony that was greater than six feet above a lower level.
Recent events (2)
- — I (S) $2150
- — Z (S) $2800
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339914970.