LANCASTER, PA —
OSHA Inspection: SWAMI CONTRACTOR, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SWAMI CONTRACTOR, INC. in 1401 MANHEIM PIKE, LANCASTER, PA 17601 (NAICS 238160). OSHA activity number 339916033.
Where did this inspection happen?
- Establishment
- SWAMI CONTRACTOR, INC.
- Site address
- 1401 MANHEIM PIKE
- City
- LANCASTER
- State
- PA
- ZIP
- 17601
- Mailing
- 1716 LOVERING AVENUE, WILMINGTON, DE 19806
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Inside of Building - The employer allowed employees to plug power cords into metal, 4 gang, junction boxes with open knockouts. The metal boxes were not securely fastened to a surface or structure as required by their listing and labeling thereby exposing employees to electrical shock hazards, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) 1401 Manheim Pike - Employees cutting wood and sheeting a roof were exposed to an electrical hazard from not having approved ground fault circuit interrupters, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) 1401 Manheim Pike - Employees using power tools were exposed to electrical hazards from a broken path to ground, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.416 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) 1401 Manheim Pike - Employees using power tools plugged into a damaged extension cord are exposed to electrical hazards from the cord sheathing removed on approximately 2 inches of the extension cord, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) Roof - An employee putting sheeting down on a flat roof was exposed to fall hazards of approximately thirteen (13) feet eight (8) inches without the use of a fall protection system, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1040.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 1401 Manheim Pike - An employee using an extension ladder to access/egress from the roof was exposed to a fall hazard from the ladder not extending three (3) feet above the upper landing surface, on or about August 22, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1040
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source