Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHER CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of SOUTHER CONSTRUCTION in TWO STORY SINGLE FAMILY HOUSE PROJECT 11535 WACHENIO CIRCLE, PALA, CA 92059 (NAICS 238130). OSHA activity number 339922213.

Watch Souther Construction — free Get an email when a new federal OSHA severe-injury report for Souther Construction is published. One employer, no account, unsubscribe in one click.
Site address
TWO STORY SINGLE FAMILY HOUSE PROJECT 11535 WACHENIO CIRCLE
City
PALA
State
CA
ZIP
92059
Mailing
13832 NICOLE VISTA, VALLEY CENTER, CA 92082
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.451 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:  Near the west and north side of the house, the employer failed to provide fall protection for employees on a wood pole scaffold platform and a wood carpenters bracket scaffold platform, exposing employees to the hazard of falling from a height of 15 feet, 5 inches from the platform to the ground.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.501 B13

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:  On the roof of the family room, The employer failed to provide fall protection for employees that used the roof to access the scaffolds and install sheating on the side of the house, exposing employees to the hazard of falling from a height of about 9 feet, 10 inches from the north eve of the roof to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.452(a)(2): Crossbracing was not installed between the inner and outer sets of poles on double pole scaffolds:  Near the north side of the house, the employer failed to provide cross bracing between every set of outer and inner poles to the double pole scaffold, exposing employees to the hazard of falling from a height of 15.5 feet from the platform to the ground.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.452 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(a)(3): Diagonal bracing in both directions was not installed across the entire inside face of double-pole scaffolds used to support loads equivalent to a uniformly distributed load of 50 pounds (222 kg) or more per square foot (929 square cm):  Near the north side of the house, the employer failed to provide diagonal bracing installed across the entire inside face to the double pole scaffold, exposing employees to the hazard of falling from a height of 15.5 feet from the platform to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 A04

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(a)(4): Diagonal bracing in both directions was not installed across the entire outside face of all double- and single-pole scaffolds:  Near the north side of the house, the employer failed to provide double diagonal bracing in both directions installed across the entire outside face to the double pole scaffold, exposing employees to the hazard of falling from a height of 15.5 feet from the platform to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:  In front of the house, a 12 foot step ladder did not extend at least three feet above the roof as it extended about 2 feet above the garage roof eve, exposing employees to the hazard of falling from a height of about 9 feet, 9 inches from the eve of the roof to the ground below.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.403 B02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  On the first level near the south side of the house, a four inch square electrical box was not used as designed as it lay on the floor instead of being secured on a surface. The boxes contained two 110 VAC electrical outlets that supplied power to 110 VAC portable power tools. Employees were exposed to the hazards of contacting electricit
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339922213.