Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: RIVERFRONT MACHINE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RIVERFRONT MACHINE INC. in 6 B WOLFER INDUSTRIAL DR., SPRING VALLEY, IL 61362 (NAICS 332116). OSHA activity number 339922486.

Watch Riverfront Machine INC. — free Get an email when a new federal OSHA severe-injury report for Riverfront Machine INC. is published. One employer, no account, unsubscribe in one click.
Site address
6 B WOLFER INDUSTRIAL DR.
City
SPRING VALLEY
State
IL
ZIP
61362
Mailing
6 B WOLFER INDUSTRIAL DR., SPRING VALLEY, IL 61362
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
70
Ownership type
A

3 citations on file for this inspection.

1910.217 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5000.00 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press.    On or about August 20, 2014, employee(s) assigned to hand-feed parts into the point of operation of the 22 Ton, Johnson Machine & Press Corp., full revolution mechanical power press (press #2), were exposed to the unguarded pinch point created between the dies. Employee(s) were exposed to hazards that were likely to result in amputation injuries.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7000

1910.332 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3150.00 · Current $1575.00 Reduced
29 CFR 1910.332(b)(1): Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments.    Employees were not adequately trained in and familiarized with required electrical safety related work practices that pertained to troubleshooting energized circuits.  Employees were exposed to contact with energized parts and/or arc flash/blast hazards.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1575
  • — Z (S) $3150

1910.333 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3150.00 · Current $1575.00 Reduced
29 CFR 1910.333(a): Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.    Employees were assigned to perform voltage testing and troubleshooting on energized circuits operating at up to 480 volts AC without appropriate protection from electrical hazards, including arc flash/blast and/or contact with energized parts.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1575
  • — Z (S) $3150

View RIVERFRONT MACHINE INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339922486.